AquaEye
®
aquaeye
TM
vodasafe.ca
instruction manual
Page 1: ...AquaEye aquaeyeTM vodasafe ca instruction manual...
Page 2: ...hile we hope that AquaEye helps saves lives there are certain things that we do not promise Other than as expressly set out in this documentation neither VodaSafe Inc nor distributors of AquaEye make...
Page 3: ...ceable parts in AquaEye Do not disassemble the device A shock hazard exists Refer all problems to authorized service personnel Subject to natural battery decline AquaEye must only be used if it operat...
Page 4: ...very high temperatures for example in a vehicle in extremely hot conditions doing so may result in permanent damage Do not attempt to open or disassemble AquaEye Doing so may result in injury or deat...
Page 5: ...to power off AquaEye C e d B a b aquaeye parts power range button a C B D E AquaEye Parts About AquaEye 2 1 1 X AquaEye 1 X Storage Case 1 X AC Adaptor 1 X AquaEye Charging Dock AquaEye is an advanced...
Page 6: ...etting up for charging The device is charged When fully charged the screen indicates battery full Remove the device and power off Place the charging dock on a counter or table The charging dock should...
Page 7: ...g scenarios will better inform you of your underwater environment and will increase success rates in finding missing persons quickly Echo Map Display will allow you to better understand your underwate...
Page 8: ...can speeds per 90 scan range short 10 m 5 sec 15 sec 30 sec medium 20 m long 50 m time 70 10m 10m 20 20 30 30 40 40 50 30 150 50 LONG Range The screen will turn on trigger use Pull the trigger to star...
Page 9: ...e f Live cursor Upon completion of a scan by releasing the trigger the cursor becomes live and acts as a compass NOTE Do not pull the trigger unless you want to begin a new scan Pulling the trigger w...
Page 10: ...When possible users should familiarize themselves with different environments to increase AquaEye knowledge Greater depth Greater depths can be scanned by tilting the wrist and pointing further down...
Page 11: ...bstacles The display can teach you about underwater obstacles which may impede AquaEye s line of sight NOTE It may be advantageous to perform scans from a particular location in your swim area based o...
Page 12: ...the sonar will not penetrate the water and echoes and objects could be missed potential causes possible solutions Cool sensor If device has been stored at high temperatures submerge device to cool se...
Page 13: ...re advance to waist deep water before scanning Dock scanning When scanning from a dock lay down on your chest and use both hands for added stability NOTE Due to the nature of the fan shaped beam the a...
Page 14: ...0 C for example in a vehicle in extremely hot conditions as AquaEye will not operate and or charge and may be permanently damaged NOTICE VodaSafe offers AquaEye training to help customers become more...
Page 15: ...ironment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accor dance with the instruction manual may cause harmful interference to radio communica...
Page 16: ...arranties are based on final approval of normal wear and tear Please contact VodaSafe or your distributor for more information VodaSafe provides annual maintenance for more information go to vodasafe...