Summary of Contents for Portable Nebulizer

Page 1: ...2018 1 Model VocalMist 1st Gen ...

Page 2: ......

Page 3: ...Clean and disinfect the saline cup and accessories before using and before storing Discontinue use of the device if the components are damaged Exposure to water can damage the battery In the event the battery becomes submerged do not use the device VocalMist Portable Nebulizer is to be used with Isotonic Saline ONLY Use of other substances may damage the unit Use of medication requires a doctor s ...

Page 4: ...er is achieved by micro metal mesh oscillation via the rapid oscillation of the circuit and piezoelectric ceramic transducer chip which sends the liquid through the metal mesh at tiny particle sizes 3μm This function immediately forms numerous tiny atomized particles to be inhaled through the mask or mouthpiece to enter the user s respiratory system Through this nebulized inhalation the saline can...

Page 5: ...quivalent particle size distribution curve of the fog particles measured under theseconditions is as follows Working Environment Storage delivery Environment Temperature 5 40 Relative Humidity 80 R H Non condensing state Atmospheric pressure 86 0 106 0 kPa Temperature 20 55 Relative Humidity 80 R H Non condensing state Atmospheric pressure 70 0 106 0 kPa Batteries Life The remaining capacity keeps...

Page 6: ...button No Name Qty 10 11 12 13 14 Mouthpiece Mask Velvet Bag USB cable 1 1 1 1 1 1 1 1 1 Note Please refer to the configuration list Warranty Card User Manual mini USB interfac 1 1 1 1 1 Warranty Card 7 Applicable scope 2017 1 Saline cup Applicable to saline nebulization for adults The elderly infants and children should use only under adult supervision ...

Page 7: ......

Page 8: ...as a work time of about 60 minutes Battery Charging 1 Continue to charge the device at least once per month even if it is out of use 2 Lithium Titanate battery has been loaded Do not disassemble Please dispose of used batteries according to the local environmental regulations Do not dispose with regular trash to avoid environmental pollution Do not dismantle or repair the equipment or components I...

Page 9: ...urn the grey cap counter clockwise to open add saline to cup then screw the cap closed again Note do not exceed the maximum capacity of the saline cup the maximum capacity can be seen on saline cup scale 1 Click ON OFF to power on start nebulization 2 Hold the nebulizer upright to keep the liquid in contact with the nebulization mesh Use any of the following three inhalation methods according to i...

Page 10: ...e liquid in contact with the nebulization mesh disc Slight movement does not affect the use but do not shake the equipment in the process of nebulization If not held upright condensation may build up on mesh causing the device to stop producing mist 2 Keep quiet and relaxed in the course of your hydration treatment 3 Please clean the spray interface section after each use see Cleaning and Disinfec...

Page 11: ...h a disinfectant wipe 4 Keep the device in dry and clean place to avoid pollution The body of the unit cannot be washed please keep it away from water The disinfectant residues should be cleaned thoroughly for next safe use Do not use distilled water or purified water that has been filtered several times 1 Put cup module including Nozzle liquid cup cover mouthpiece masks and other parts into 40 C ...

Page 12: ... if any irregularities are encountered seek a solution in accordance with Chapter 8 e If the nebulizer still does not work properly please contact our company or the dealer f Do not expose the nebulizer and accessories to corrosive liquids and gases saline cup and other ...

Page 13: ...d our list and damaged by the user s personal causes Please refer to the Troubleshooting section when there are problems and contact the service center for maintenance Do not attempt to repair theequipment personally Please clean and disinfect the unit after use and refer to the clean and disinfect chapter sterile isotonic saline only Please do not vigorously move the device when there is liquid i...

Page 14: ...he device especially the USB connector Please use qualified manufacturers of lithium battery power charger output5 0V 1 0A The nebulizer has no moisture and dust function and the product should not be stored in a wet or dusty environment Do not drop and avoid strong impact on the device cup as water Please place the VocalMist in a place where children and infants can not reach it Do not touch the ...

Page 15: ...e not allowed and may cause damage to the device 1 Check if the nebulizer is charged 2 Check if the liquid cup is filled 1 Confirm that the cup been filled only with saline 2 Tilt the unit so that the liquid is in contact with the spray mesh 3 The spray mesh maybe blocked by minerals You can drop 2 or 3 drops of white vinegar into the saline cup with 3 6ml warm water then fully nebuilze Rinse the ...

Page 16: ...thin 1 Year The device is warranted by the manufacturer to be free from material defects and workmanship defects appearing within 1 year from the date of purchase when used in accordance with the instructions provided with the device Feellife Health Inc will at our option repair or replace without charge Any repair service out of the scope of warranty will be charged accordingly Please contact the...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ......

Page 21: ...21 Seri al N o Seri al N o E mai l i nfo feel l i fe com Seri al N o Seri al N o E mai l i nfo feel l i fe com 6 Water 6 Water ...

Page 22: ...22 Product Model Inspection date Inspector CERTIFICATE OF INSPECTION Feellife Medical Inc mini Air 360 ...

Page 23: ...23 Child mask Mouthpiece User manual Warranty card Certificate of inspection Micro USB cable Quantity If Included Yes No Configuration list User Guidance Item Unit Adult mask Velvet bag cup Saline ...

Page 24: ......