background image

    Technical Support 

Subject 

RAPTAIR-MF Error Codes and Symptoms 

 

Document 

Version 

Department 

Revision Details 

Revised by 

Tech 

Engineering 

Implemented 

EXT-MF-015 

Tech 

Update Systems affected 

MSP 

N/A 

N/A 

25 June 2018 

 

Page 

7

 of 

7

 

Knowledge Base

www.kb.vmacair.com

 

Email

[email protected] 

Web: 

www.vmacair.com

  

Technical Support: 

1(888)241-2289

  

Toll Free:

1(800)738-8622

  Fax: 1(877)740-3202 

 

Setting 

Description 

Adjustment 

Default 

Allow Low Battery 

Restart  

In Standby, allow the 

engine to restart 

based on low battery 

level  

Enabled/Disabled  

Enabled 

Battery Restart Lower 

Threshold  

Engine will restart if 

below this threshold 

for 30 seconds in 

Standby  

10.0 

– 14.0V @ 0.1V 
increments  

12.1V 

Battery Restart Upper 

Threshold  

System will start 

duration timer if above 

value  

10.0 

– 15.0V @ 0.1V 
increments  

12.8V 

Battery Restart 

Duration  

Once above Upper 

Threshold, stay 

running for duration to 

charge battery  

1, 2, 5, 10, 15, 30 

minutes  

2 min 

 

Summary of Contents for RAPTAIR-MF

Page 1: ...NOT start the compressor until the error is cleared When an error is present the WARNING LED will flash on off and the screen will display ERRORS DETECTED followed by the following list of errors The...

Page 2: ...888 241 2289 Toll Free 1 800 738 8622 Fax 1 877 740 3202 Name __________________________ Phone ______________________ Company _______________________ Email Fax ____________________ Date _____________...

Page 3: ...ity of a plug 12 AIR PRESS SIGNAL VOLTAGE LOW Low voltage reading on the air pressure transducer 13 AIR PRESS SIGNAL VOLTAGE HIGH Low voltage reading on the air pressure transducer 14 AIR PRESS SIGNAL...

Page 4: ...E TOO LOW The battery voltage is below threshold for 5 seconds see Section 7 7 for threshold adjustment 46 ENGINE RESTART DUE TO COLD The engine has auto restarted due to the low internal temperature...

Page 5: ...ature shut down Frequent over temperature shut down Low oil level Check oil level with equipment on level ground Restricted oil lines Check for kinked or pinched lines Plugged oil filter Replace oil f...

Page 6: ...able parameters will reset to factory settings Pressing ENTER on this screen will display CANCEL Pressing NEXT will show CONFIRM RESET Pressing BACK will display CANCEL again Select the desired option...

Page 7: ...8 8622 Fax 1 877 740 3202 Setting Description Adjustment Default Allow Low Battery Restart In Standby allow the engine to restart based on low battery level Enabled Disabled Enabled Battery Restart Lo...