VMAC – Vehicle Mounted Air Compressors
Toll Free:
1-888-241-2289 Local: 1-250-740-3200
Fax: 1-250-740-3201
33
6.2.3 Pressure Line Sizing
Choose a pressure line size from Table 13 (based on 20 ft/sec fluid
velocity), then upsize the line, if necessary, using Table 14.
Maximum GPM
Pressure Line Size
8-12 1/2”
13-18 5/8”
19-22 3/4”
Table 13
Temperate
Climate
Not Critical. Size as per Table 13
Cold Climate 3/4”
No Tank Preheat. Line
sizing is based on strict
adherence to Note 1 of
Table 5
3/4”
GPM during
pump startup
Pressure Line
size
8 (or less)
3/4” up to 7ft
1” above 7ft
12
3/4” up to 5ft
1” above 5ft
16
3/4” up to 3.5ft
1” up to 12ft
1-1/4” above 12ft
Extreme
Cold Climate With Tank and Suction
line preheat. (AW32 oil)
Pressure line not
preheated.
20
3/4” up to 3ft
1” up to 9ft
1-1/4” above 9ft
Table 14
6.3 Hydraulic System Filtration
Use a 10 micron return line hydraulic oil filter; 25 micron is
acceptable. Flow rating of the filter must be equal to or greater than
the maximum GPM at which the system will be operated. Use only a
filter that is specifically intended for hydraulic systems.