Summary of Contents for KC-7180V1-MS

Page 1: ...iNStRuctioN mANuAL moDEL Kc 7180V1 mS COPYRIGHT 2013 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC high output StAtioNARY 7 5 pEAK hp 80 gALLoN AiR compRESSoR 11 2014 ...

Page 2: ...d lack of maintenance King Canada shall in no event be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To take advantage of this limited warranty return the product at your expense together with your dated proof of purshase to an authorized King Canada service center Contact your retailer or visit our web site...

Page 3: ...y system RiSK oF buRNS WhAt cAN hAppEN Touching exposed metal such as the compressor head or outlet tubes can result in serious burns hoW to pREVENt it Never touch any exposed metal parts on compressor during or immediately after operation The compressor will remain hot several minutes after use Do not reach around protective shrouds or attempt maintenance until the compressor has cooled down comp...

Page 4: ...formation below Warning Do not attempt to hard wire this compressor yourself unless you are a qualified electrician Overheating short circuiting and fire damage will result from inadequate wiring Electrical wiring codes local or provincial may differ from area to area Source wiring plug and protector must be rated for at least the amperage and voltage indicated on the main technical nameplate Use ...

Page 5: ...ut iNto SERVicE AFtER REpLAciNg thE chEcK VALVE AND WhEN A piStoN oR A cYLiNDER SLEEVE ARE REpLAcED 1 Make sure the pressure switch lever A Fig 3 is in the OFF position 2 Make sure the compressor is properly wired to electrical source and grounded if a power cord was installed plug the power cord into a grounded 240V branch circuit receptacle 3 Make sure the oil level in the crankcase reaches the ...

Page 6: ...e power to the automatic pressure switch and OFF to remove power at the end of each use pRESSuRE SWitch c Fig 9 The pressure switch automatically starts the motor when the tank pressure drops below the factory set Cut In pressure It also stops the motor when the air tank pressure reaches the factory set Cut Out pressure ASmE SAFEtY VALVE D Fig 9 If the pressure switch does not shut off the air com...

Page 7: ... be in the centre of the red dot of oil sight glass 2 Drain condensation from tank 3 Check for any unusual noise or vibration 4 Be sure all nuts and bolts are tight monthly 1 Inspect air system for leaks by applying soapy water to all joints Tighten those joints if leakage is observed initial oil change must be done after the first 100 hours 1 Once initial oil change is done after 100 hours of ope...

Page 8: ...sure Restricted air filter Wrong oil viscosity Oil level too high Crankcase breather valve malfunction Worn piston rings Piston rings not seated CORRECTIVE ACTION Check voltage or eliminate extension cord or reset Check wiring connections Wait for motor to cool then press the reset button restart Drain tank of air pressure Check valve manually by pulling If condition persists replace Close drain c...

Reviews: