    Technical Support 

Subject 

PREDATAIR Error Codes and Symptoms 

 

Document 

Version 

Department 

Revision Details 

Revised by 

Tech 

Engineering 

Implemented 

EXT-PRED-016 

Tech 

Document Release 

SP 18 Aug 2015 

DB 18 Aug 2015 

N/A 

18 Aug 2015 

 

Page 

4

 of 

8

 

Knowledge Base

www.kb.vmacair.com

 

Email

[email protected] 

Web: 

www.vmacair.com

  

Technical Support: 

1(888)241-2289

  

Toll Free:

1(800)738-8622

  Fax: 1(877)740-3202 

 

 

Display box messages 

 

Power ON, System OFF

 

Message/Problem 

Possible Causes 

Corrective Action 

HYD OIL TOO COLD 

The hydraulic oil 
temperature is below 
5

o

F (-15

o

C) 

Pre-heat the hydraulic oil before running the 
system. 

No power to display 
box 

Fuse blown or bad 
connection 

Check components, replace fuse inside 
PREDATAIR 

 

ON button pressed/Initial start-up

 

Message/Problem 

Possible Causes 

Corrective Action 

SOFT START XXXPSI 

The system has 
started, but the 
compressor oil 
temperature is still 
cool. 

The system is in “Unload” Mode, until the 
compressor has come up to temperature 
+122

o

F(50

o

C) 

HYD OIL TOO COLD 

The hydraulic oil is 
below -13

o

F (-25

o

C). 

The system is cautioning the operator to preheat the 
hydraulic oil before starting the PTO system. The 
Cold Climate Kit (A700146) can be installed to 
speed warm-up once the hydraulic oil temperature 
has reached 

–13

o

F(-25

o

C). 

HYD OIL WARMING, 
HYD XXXF/XXXC 

The hydraulic oil is 
between -13

o

F(-25

o

C) 

and +5

o

F(-15

o

C) 

Keep circulating hydraulic fluid until the system 
warms sufficiently to start. If installed, the Cold 
Climate Kit (A700146) will speed warm-up. The 
Predatair won’t start until the hydraulic oil has 
warmed to +5

o

F(- 15

o

C). 

PREDATAIR does not 
start when the ON 
button is pressed. 

Inappropriate 
conditions for start-up. 

Check display box for messages. 

Hydraulic solenoid 
failure. 

. Check solenoid and connections. 

Hydraulic motor or 
compressor seized. 

Check motor and compressor will roll-over. 

 

Running 

Message/Problem 

Possible Causes 

Corrective Action 

STANDBY XXXPSI 

The air pressure 
stayed above the 
restart pressure for 
the duration of the 
standby delay time. 

The hydraulic solenoid is off, and the system is 
monitoring air pressure and compressor and 
hydraulic oil temperatures. If the air pressure 
drops below the restart pressure, or the 
compressor oil temperature drops below its 
minimum, it will restart and rebuild air. 

Air pressur

e won’t build 

past approx. 40psi. 

The system is in 
SOFT START. 

Wait for the compressor to warm up. 

Unload solenoid on 
inlet valve has failed 

Check solenoid and wiring. 

Summary of Contents for AIR INNOVATED H400001

Page 1: ...oting 7 Temporarily override the compressor temperature sensor 7 Temporarily override the hydraulic temperature sensor 7 Electrical Schematic 8 Overview General error codes symptoms and trouble shooti...

Page 2: ...______________________ Company _______________________ Email Fax ____________________ Date ________________ Error Code Error 1 Compressor has Over Temped 138C 2 Hydraulic has Over Temped 88C 3 Not Use...

Page 3: ...On Steady Off Operating None Off On Steady Compressor Off Fan On Compressor Too Hot Off Flashes On Off continuously Compressor Off Fan On Hydraulic Oil Too Hot One Flash Pause One Flash continuously...

Page 4: ...rting the PTO system The Cold Climate Kit A700146 can be installed to speed warm up once the hydraulic oil temperature has reached 13oF 25oC HYD OIL WARMING HYD XXXF XXXC The hydraulic oil is between...

Page 5: ...correct amount of hydraulic flow for the desired CFM Ensure that engine rpm is being maintained when load is applied Unload Solenoid Failure Check solenoid and wiring General Message Problem Possible...

Page 6: ...r or bad wiring connection Check the pressure sensor and wiring connections CONNECTION ERR Failed control box display box or bad wiring connection Failed control box display box or bad wiring connecti...

Page 7: ...probe is disabled you need to back out of the DIAGNOSTIC screen by pressing both the ON and OFF buttons simultaneously You will need to do this twice to back right out to the main screen To reset the...

Page 8: ...d by Tech Engineering Implemented EXT PRED 016 A Tech Document Release SP 18 Aug 2015 DB 18 Aug 2015 N A 18 Aug 2015 Page 8 of 8 Knowledge Base www kb vmacair com Email tech vmacair com Web www vmacai...

Reviews: