Technical Support
Subject
PREDATAIR Error Codes and Symptoms
Document
Version
Department
Revision Details
Revised by
Tech
Engineering
Implemented
EXT-PRED-016
A
Tech
Document Release
SP 18 Aug 2015
DB 18 Aug 2015
N/A
18 Aug 2015
Page
3
of
8
Knowledge Base:
Email:
Toll Free:
Flash Code Table
Some early models of PREDATIAR were not equipped with a Display Box. These models will have a
GREEN and RED LED on the top of the unit. Use the table below to determine the error code.
Green
Red
State
Problem
On Steady
Off
Operating
None
Off
On Steady
Compressor Off
Fan On
Compressor Too Hot
Off
Flashes On-Off
continuously
Compressor Off
Fan On
Hydraulic Oil Too Hot
One Flash-Pause-One
Flash continuously
..
Off
Compressor Off
Fan On
High Pressure Start Warning
Flashes On-Off
continuously
Off
Compressor Off
Fan OFF
Preheater on (If equipped)
Cold Start Mode
Off
One Flash-Pause-One
Flash continuously
Compressor Off
Fan OFF - Probe Open
Fan On
– Probe Shorted
Compressor Temperature
Probe Failure (Service Req.)
Off
Two Flashes-Pause-Two
Flashes continuously
Compressor Off
Fan OFF - Probe Open
Fan On
– Probe Shorted
Hydraulic Cooler
Temperature Probe Failure
(Service Req.)
Off
Three Flashes-Pause-
Three Flashes
continuously
Compressor Off
Fan OFF - Probe Open
Fan On
– Probe Shorted
Hydraulic Manifold
Temperature Probe Failure
(Service Req.)