The fan with the time switch and humidity sensor TH - the fan starts after the external switch, e.g. light switch,
has been actuated. The signal from the switch applies the control voltage to the input terminal LT (ST). The fan
also starts when the room humidity is above the switch-on humidity, adjustable from 60% to 90%. After
disconnecting the control voltage or after reducing the humidity, the fan continues to operate for the set
time, from 2 to 30 minutes.
To recruitment
of maximum humidity
Setpoint turn the potentiometer knob up to the H max position (90%).
To adjust the run-on time, turn the rotary knob of the potentiometer T clockwise to increase and
counterclockwise to reduce the run-on time accordingly, Fig. 12. To adjust the humidity setpoint, turn the
potentiometer rotary knob H clockwise to enlarge and counterclockwise corresponding to the reduction of
the moisture threshold, Fig. 1
2
.
Warning! The circuit board of the timer is under mains voltage! Before any setting work, disconnect the fan from the
power supply! A plastic screwdriver for changing the settings is included with the fan. Use the plastic screwdriver to set
the switch-on delay time, follow-up time and the humidity setpoint, Fig. 14.
Do not use a metal screwdriver, knife, etc. to avoid damaging the electronic board.
6th
Summary of Contents for 100 AV
Page 1: ...100 AV DE AXIAL FAN User guide www vlano de ...
Page 10: ...1 10 ...
Page 11: ...L N QF 2 3 4th 5 6th 7th 11 ...
Page 12: ... V _ default L N S QF QF S L N 8th T TH L N S QF QF L LT ST S N 9 12th ...
Page 13: ...T TH T H 2min 30 min 60 90 10 Т1 11 12th 13 13 H ...
Page 14: ...MAINTENANCE ENTRIES QF 14th 15th 16 17th 18th 19th 14th ...
Page 15: ...Sign of the customer Sold Name and stamp of the seller manufacturing date Date of sale 15th ...