Vlano 100 AV Operating Manual Download Page 6

DE

The fan with the time switch and humidity sensor TH - the fan starts after the external switch, e.g. light switch, 

has been actuated. The signal from the switch applies the control voltage to the input terminal LT (ST). The fan 

also starts when the room humidity is above the switch-on humidity, adjustable from 60% to 90%. After 

disconnecting the control voltage or after reducing the humidity, the fan continues to operate for the set 

time, from 2 to 30 minutes.

To recruitment 

of maximum humidity

Setpoint turn the potentiometer knob up to the H max position (90%).

To adjust the run-on time, turn the rotary knob of the potentiometer T clockwise to increase and 

counterclockwise to reduce the run-on time accordingly, Fig. 12. To adjust the humidity setpoint, turn the 

potentiometer rotary knob H clockwise to enlarge and counterclockwise corresponding to the reduction of 

the moisture threshold, Fig. 1

2

.

Warning! The circuit board of the timer is under mains voltage! Before any setting work, disconnect the fan from the 
power supply! A plastic screwdriver for changing the settings is included with the fan. Use the plastic screwdriver to set 
the switch-on delay time, follow-up time and the humidity setpoint, Fig. 14.

Do not use a metal screwdriver, knife, etc. to avoid damaging the electronic board.

6th

Summary of Contents for 100 AV

Page 1: ...100 AV DE AXIAL FAN User guide www vlano de ...

Page 2: ...ry or mental capabilities The device is not intended for use by persons with insufficient experience or specialist knowledge unless they are under control or have been instructed by a person responsible for their safety Children must be supervised and are not allowed to play with the device Take measures to ensure that smoke carbon oxide gases and other flammable substances cannot enter the room t...

Page 3: ...n series AV Extra options _ Default T overrun switch TH humidity sensor and overrun switch Modifications of the motor and the impeller Example of the description of the designation 100 AV T fans with the outlet nozzle diameter 100 AV series equipped with an overrun switch 3 ...

Page 4: ... these operating instructions is an axial fan for Venting of small and medium sized living spaces that are heated in winter The fan is made of white plastic The fan is compatible with pipes Ø 100 125 150 mm depending on the flange size of the fan The design of the fans is constantly being improved and updated and some models may differ from what is described in this manual OPERATING INSTRUCTIONS T...

Page 5: ... set the follow up time and the humidity setpoint if necessary Fig 8 14 Step 5 put the front grille back on the case Fig 15 Step 6 Apply power to the fan Fig 16 DESCRIPTION OF TERMINALS ON THE CIRCUIT DIAGRAMS L phase only for mains 220 240 V N 0 only for mains 220 240 V LT ST control line of the timer S external off on switch ELECTRONIC CONTROL LOGIC The fan with the time switch T the fan starts ...

Page 6: ...x position 90 To adjust the run on time turn the rotary knob of the potentiometer T clockwise to increase and counterclockwise to reduce the run on time accordingly Fig 12 To adjust the humidity setpoint turn the potentiometer rotary knob H clockwise to enlarge and counterclockwise corresponding to the reduction of the moisture threshold Fig 12 Warning The circuit board of the timer is under mains...

Page 7: ...d a relative humidity of max 80 Dust acid and alkali vapors which can cause corrosion are not permitted in the storage area MANUFACTURER S WARRANTY With the purchase of this product the consumer confirms that he has the operating conditions operating regulations and operating storage transport assembly adjustment connection maintenance repair requirements and guarantee obligations that are specifi...

Page 8: ...the consumer does not present the product in its entirety as stated in the operating instructions or other document including the components dismantled by the consumer if the model the brand of the product and the information on the packaging and in the instruction manual or any other document that replaces the instruction manual do not match if the product is not serviced in good time dust conden...

Page 9: ...e Lack of Payment receiptconfirming the purchase indicating the date of sale The manufacturer is liable for defects that arose through his fault before the product was handed over to the consumer The manufacturer is not liable for defects that arise after delivery of the product to the consumer as a result of non compliance with transport storage assembly and operating regulations actions by third...

Page 10: ...1 10 ...

Page 11: ...L N QF 2 3 4th 5 6th 7th 11 ...

Page 12: ... V _ default L N S QF QF S L N 8th T TH L N S QF QF L LT ST S N 9 12th ...

Page 13: ...T TH T H 2min 30 min 60 90 10 Т1 11 12th 13 13 H ...

Page 14: ...MAINTENANCE ENTRIES QF 14th 15th 16 17th 18th 19th 14th ...

Page 15: ...Sign of the customer Sold Name and stamp of the seller manufacturing date Date of sale 15th ...

Page 16: ...Acceptance certificate T 100 125 150 AV TH The fan is recognized as operational www vlano de VLANO01 M model DE 01 ...

Reviews: