background image

4. MASTER - key memorizing

1. Keys memorizing

2. Erasing of keys

3. Erasing of

keys

Entering into programming and all available system setup and service settings transitions are shown on
Figures 5 - 7.

To enter programming mode:

DOOR OPEN

“Programming is finished”

To change the doorstation volume:

Apply the Master-key in Intercom mode

ABBREVIATIONS

The MASTER - key enables easy entering into programming and doorstation volume adjustment.

- Pick up the handset of the monitor and check duplex intercom.

- Press the

button on the monitor 7 times.

Each time hold the button until a beep.

- After the screen switches off, hang up the handset.

- The doorstation produces beeps and enables Voice MENU. Follow Menu messages to perform service settings and

system setup. Setup and settings contents, function and order are given in part “Programming”.

- After the programming is complete, press the

button.

sounds and the doorstation returns into stand-by mode.

You can enter programming mode using the MASTER-key memorized during the first programming.

-

for more than 5 seconds. Press

or

the volume by one step. The number of step is pronounced.
9 steps are available.

Press

again, if needed. Hang up the handset when finished.

LN

Intercom line

VO

VIDEO OUT

GND

GROUND

VG

VIDEO GROUND

+E

Power for doorstation

LC

Lock Control

Ec

Power for built-in camera

OP

OPEN

Service  settings

being applied to the reader

all

A

A

A

once to decrease

twice

to increase

Figure 3 - Doorstation

with monitor

BVD-

7x

VIZIT-M430C

and electromechanical lock

40

-18

+18

+12

-12

50 V

1 A

Power supply

BPD18/12-1-1

LN-
GND

LN+

VI1
+E
DATA
Ec1
Ec2
GND
VI2

Monitor

VIZIT-M430C

1
2
3
4
5

1
2
2
1

1

2

1

2

2

1

A

B

C

D

1

2

3

4

6

1

2

25

50

100

0.2

0.4

0.8

0.8

1.5

Min. cross-sections

of wires, mm

2

Length
of cables

0.4

A+B
C+D

meters

Doorstation

BVD-407x

LN

GND

+E
Ec

LC

VO
VG

6

5

OP

Summary of Contents for BVD-407 Series

Page 1: ...re supported Only keys DS1990A iButton from Dallas Semiconductor are supported Intercom between visitor and subscriber Door zone videomonitoring Illumination for the camera The entrance door unlocking...

Page 2: ...ine carefully the operating instruction for the installation order and wiring diagrams Mounting dimensions are shown on Figure 1 in millimeters The doorstation center should be approximately 1 5 meter...

Page 3: ...default Electromechanical lock is released when voltage across its terminals is switched on Default setting is 7 seconds 1 second is recommended for electromechanical lock Default setting is System se...

Page 4: ...in part Programming After the programming is complete press the button sounds and the doorstation returns into stand by mode You can enter programming mode using the MASTER key memorized during the fi...

Page 5: ...f cables 0 4 A B C D E meters 50 2 1 1 2 18 18 12 12 Power supply BPD18 12 1 1 Doorstation BVD 407x LN GND E Ec LC VO VG OP 2 1 3 3 2 E Figure 5 Transitions between system setup service settings and P...

Page 6: ...1 A 6 MASTER key memorizing strokes Beep Apply a key to be the MASTER key which is Figure 6 Transitions in system setup mode Figure 7 Transitions in service settings mode 1 Memorizing of keys stroke o...

Page 7: ...e system goes into Stand by mode Check operation of all keys If the applied key is memorized the door unlocks Come in please sounds at the doorstation and a short beep sounds at the monitor If the app...

Reviews: