CONFIDENTIAL – DO NOT COPY
Page 2-3
File No. SG-0273
9-2. OPERATING PRECAUTIONS
(1) The spike noise causes the mis-operation of circuits. It should be lower
than following voltage:
V=±200mV(Over and under shoot voltage)
(2) Brightness depends on the PATTERN.
(3) Be careful for condensation at sudden temperature change. Condensation
makes damage to electrical contacted parts. And after fading condensation,
smear or spot will occur.
(4) When fixed patterns are displayed for a long time, remnant image is likely
to occur.
(5) Module has high frequency circuits. System manufacturers shall do
sufficient suppression to the electromagnetic interference. Grounding and
shielding methods may be important to minimize the interference.
9-3. HANDLING PRECAUTIONS FOR PROTECTION
(1) The protection film is attached to the bezel with a small masking tape.
When the protection film is peeled off, static electricity is generated
between the film and polarizer. This should be peeled off slowly and
carefully by people who are electrically grounded and with well ion-blown
equipment or in such a condition, etc.
(2) When the module with protection film attached is stored for a long time,
sometimes there remains a very small amount of glue still on the bezel after
the protection film is peeled off.
(3) You can remove the glue easily. When the glue remains on the bezel
surface or its vestige is recognized, please wipe them off with absorbent
cotton waste or other soft material like chamois soaked with
normal-hexane.