6. ENVIRONMENT
Operating Temperature: 5c~35c (Ambient)
Operating Humidity: Ta= 35 °C, 90%RH (Non-condensing)
Operating Altitude: 0 - 14,000 feet (Non-Operating)
7. Dimensions (Physical dimension)
With Base
Without Base
a. Height
700mm
665.7mm
b. Width
1024.5mm
1024.5mm
c. Depth
243.5mm
96mm
8. Weight (Physical weight)
a. Net 17 +/- 0.5 kg
b. Gross 21.5 +/- 1.0 kg
9. Precautions
Please pay attention to the followings when you use this TFT LCD module.
9-1. Mounting Precautions
(1) You must mount a module using holes arranged in four cornersor four sides.
(2) You should consider the mounting structure so that uneven force (ex. Twisted
stress) is not applied to the module. And the case on which a module is
mounted should have sufficient strength so that external force is not
transmitted directly to the module.
(3) Please attach the surface transparent protective plate to the surface in order to
protect the polarizer. Transparent protective plate should have sufficient
strength in order to the resist external force.
(4) You should adopt radiation structure to satisfy the temperature specification.
(5) Acetic acid type and chlorine type materials for the cover case are not
desirable because the former generates corrosive gas of attacking the
polarizer at high temperature and the latter causes circuit break by
electro-chemical reaction.
(6) Do not touch, push or rub the exposed polarizers with glass, tweezers or
anything harder than HB pencil lead. And please do not rub with dust clothes