CONFIDENTIAL – DO NOT COPY
Page 2-3
File No. SG-0292
(4). When fixed patterns are displayed for a long time, remnant image is likely
to occur.
(5). Module has high frequency circuits. Sufficient suppression to the
electromagnetic interference shall be done by system manufacturers.
Grounding and shielding methods may be important to minimized the
interference.
(6). Please do not give any mechanical and/or acoustical impact to LCM.
Otherwise, LCM can’t be operated its full characteristics perfectly.
(7). A screw which is fastened up the steels should be a machine screw. (if not,
it can causes conductive particles and deal LCM a fatal blow)
(8). Please do not set LCD on its edge.
(9). It is recommended to avoid the signal cable and conductive material over
the inverter transformer for it can cause the abnormal display and
temperature rising.
(10). Partial darkness may happen during 3~5 minutes when LCM is operated
initially in condition that luminance is under 40% at low temperature (under
5
℃
). This phenomenon which disappears naturally after 3~5 minutes is
not a problem about reliability but LCD characteristic
2. HANDLING PRECAUTIONS FOR PROTECTION FILM
(1). The protection film is attached to the bezel with a small masking tape
.
When the protection film is peeled off, static electricity is generated
between the film and polarizer. This should be peeled off slowly and
carefully by people who are electrically grounded and with well ion-blown
equipment or in such a condition, etc.
(2). When the module with protection film attached is stored for a long time,
sometimes there remains a very small amount of glue still on the bezel
after the protection film is peeled off.
(3). You can remove the glue easily. When the glue remains on the bezel
surface or its vestige is recognized, please wipe them off with absorbent
cotton waste or other soft material like chamois soaked with normal
hexane.