A.

 

Only persons with appropriate authorization may connect the lift to a 230V power supply. Connections must follow the diagram 

and the instructions.  

                                                                    

 

 

4.

 

BEFORE PROGRAMMING 

1.

 

After SLIM LIFT 12/1640 or SLIM LIFT 10/3250 lift is installed, connect the lift to the power supply according to the diagram above.  

2.

 

After lift was connected to power supply, lift controller is ready to start programming in 60 seconds (after this time, turn the power 
“off” and “on” again to start programming again). 

ATTENTION! 

don’t make a pause in programming more than 3 minutes between programming steps.  After that time of delay 

(3 min.) control box automaticaly exits programming mode. It is needed to run programming from the start.                        
 

 

5.

 

„UP” and „DOWN” positions PROGRAMMING: 

1.

 

After power supply  230V is connected LED diode will flash 10 times and turn off.  

2.

 

Press and hold  „PROGRAMMING button” untill  LED diode will flash 5 times. Stop holding button. LED diode will light flashing 10 
times and start light steady light,  confirming enter PROGMAMMING MODE” status.    

3.

 

„UP” position PROGRAMMING

:

 USING POTENTIAL FREE or VOLTAGE CONTROL,  set „UP” position  of Slim lift. To confirm 

setup zatwierdzić, press „PROGRAMMING button”, LED diode will flash  4 times, start light steady light (control box is waiting for 
next steps). 

4.

 

 „DOWN” position PROGRAMMING

:

 USING POTENTIAL FREE or VOLTAGE CONTROL,  set „DOWN” position  of Slim 

lift. To confirm setup press „PROGRAMMING button”, LED diode will flash 10 times and turn off. (It is confirmation of setup 
„UP” and „DOWN” positions and exit PROGMAMMING MODE” status).

 

Programming is finished

. SLIM-Lift is ready to work.   

6.

 

PROTECTION:

 

A.

 

THERMAL – switches off lift motor after 4 minutes of 
continuous lift operation. After the motor has overheated 
and automatically switched off, leave the lift for about 10-
15 minutes without starting. 

 

B.

 

LIMIT SWITCHES - The lift has motor limit switches that 
set the maximum upper and lower elevators. 

ATTENTION! 

 Adjusting motor limit switchers prohibited! 

LIMIT SWEITCHES are sealed with warranty seal, removing 
seal voids warranty! 

SAFTETY BREAK. In a power supply failure, lift stops immediately. Re-switching on the power supply allows further operation of the lift. 

Attention!

 Check the cables layout and place them securely so that they do not get between the lift arms - this can damage the cables 

and the lift. 

7.

 

TECHNICAL DATA:

 

Range of movement: 

SLIM 12/1640 – 1640mm 
SLIM 10/3250 – 3250mm 

Capacity: 

SLIM 12/1640 – 12kg 

SLIM 10/3250 – 10kg 

Adjustment 

LIMIT SWITCHES: UP - DOWN. 

Projector ro/- 15°. 
 

Power supply: 

230V / 50 HZ  

Manufactured: VIZ-ART Automation 

tel.+48 22/6138899 www.viz-art.pl

 

3/4 

 

LED diode 
 
PROGRAMMING  
button 
 

 

Summary of Contents for SLIM Series

Page 1: ...t plate A Drill holes and install expansion plugs from the kit B Raise the lift and screw to the fixed ceiling in sites marked as B C Install the universal projector holder using screws fromthe kit D Install the projector and adapter on the SLIM lift E Insert elements D into holes C and turn the assembly F Turn On the projector and rotating the adapter on the lift SLIM LIFT Projector Lift SLIM 12 ...

Page 2: ...jector and adapter must be mounted as on theillustration elements F must be below element E J Small nuts G 3 pcs are used to adjust the projector sposition in three axes 2 Ceiling closing panel installation A Ceiling closing panel H Install to the base of the SLIM lift by screwing it in four places use screws nuts and washers from the kit B Adjustment of the closing panel allows it to be adapted t...

Page 3: ... start light steady light control box is waiting for next steps 4 DOWN position PROGRAMMING USING POTENTIAL FREE or VOLTAGE CONTROL set DOWN position of Slim lift To confirm setup press PROGRAMMING button LED diode will flash 10 times and turn off It is confirmation of setup UP and DOWN positions and exit PROGMAMMING MODE status Programming is finished SLIM Lift is ready to work 6 PROTECTION A THE...

Page 4: ...pecific lift model After mounting the equipment before first use check if it is mounted as per the instructions and level If the equipment is not level adjust the mounting Do not use equipment that is not properly installed Do not modify or unscrew elements of the equipment as this may cause a risk of permanent damage to the equipment and or the safety of the users WARRANTY CONDITIONS The warranty...

Reviews: