![Vixel InSpeed 335 Installation & Configuration Manual Download Page 52](http://html1.mh-extra.com/html/vixel/inspeed-335/inspeed-335_installation-and-configuration-manual_1041067052.webp)
Vixel Model 335 Installation & Configuration Guide
CHAPTER 3
Management
49
Displaying Ports
The Show Port command displays all information concerning a specific port and allows
you to change the port policies.
To configure the currently selected port, type
po
at the prompt.To activate the show port
command for a specific port, type
po x
(where
x
is the port number) at the prompt.
port 1 (switch ID=28000070)
module : none
state : bypassed
zone : 1
PLL : nolock
transceiver LED : off
fault LED : off
cascade state : none
connect type : none
insert count : 0
clk delta ppm : 0
rx frame count : 2
connect attempts : 0
connects busy : 0
CRC errors : 2
bad OS errors : 0
port util avg : 0
port util high : 0
port util low : 0
port util last : 0
(1) Control : auto
(2) Beacon : off
(3) Transmitter : on
(4) Cascade mode : tree
(5) LIP on insert : enabled
(6) Test before insert : disabled
(7) Overlapping zones : 0x004
(8) Util period avg : 100
(9) Util period stats : 100
(10) Reset counters