Vivreau V3-205 Owner'S Manual Download Page 9

V3-205 Dispensing System Owner’s Manual

   

9

Section 3

Technical Specifications

TECHNICAL SPECIFICATIONS

GENERAL DESCRIPTION

The Vivreau V3-205 Dispensing System is 
designed to provide Chilled Still and Sparkling 
Water on demand.  
Model V3-205 is a Water Dispensing System 
designed for under-counter installation with the 
CO

2

 Cylinder, CO

2

 Regulator and Water Filter 

mounted in a cabinet below the unit. 

This unit can be connected to a bulk CO

2

 system, in 

lieu of a CO

2

 Cylinder and regulator.

This system is made up of several components 
that will fit under a standard minimum 24” wide 
base-cabinet section.
The system has been designed for operation at 
ambient temperatures up to 90ºF.

Dispensing Specifications

Description

Specification

Chilled still water 

ΔT=18 °F @ 15.8 gal/h 

Chilled sparkling water 

ΔT=18 °F @ 15.8 gal/h 

Water Pressure at Dispensing Head 

5 PSI

Operating Conditions

Description

Specification

Temperature 

60 – 90°F 

Relative Humidity 

60% (max.)

Water Supply Requirements

Description

Requirements

1/2” FNPT connection with Ball Valve

1/2”

PSI (min.)

50

GPH (min.)

80

Temperature (max.)

60°F

CO

2

 Operating Pressure

Description

Requirements

Pressure

65-70 PSI

Supply Pressure (Bulk System) 

100 PSI (min.)

Dispenser Head Specifications

Description

Requirements

Height 

19.3”

Distance Nozzle to Drip Tray 

12.3”

Summary of Contents for V3-205

Page 1: ...V3 Dispensing System Owner s Manual MODEL V3 205 Freshly drawn Traditionally Served Environmentally Friendly Specially Branded 170501 Model V3 205...

Page 2: ...IMPORTANT_______________ The information contained in this manual is specific to your system It is IMPORTANT you READ FOLLOW and UNDERSTAND the instructions given This manual and all material provided...

Page 3: ...ensing System Owner s Manual 3 TABLE OF CONTENTS SAFETY PRECAUTIONS 5 GENERAL INFORMATION 7 TECHNICAL SPECIFICATIONS 9 PRE INSTALLATION REQUIREMENTS 11 OPERATING INSTRUCTIONS 13 MAINTENANCE 17 TROUBLE...

Page 4: ...4 V3 205 Dispensing System Owner s Manual...

Page 5: ...rained and certified electrical plumbing and refrigeration technicians should service this unit WARNING ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL CODES FAILURE TO COMPLY COULD RESULT...

Page 6: ...6 V3 205 Dispensing System Owner s Manual Section 1 Safety Precautions...

Page 7: ...this manual in a clearly identified and safe place throughout the working life of the unit so that it will always be available as needed The manufacturer reserves the right to make modifications to th...

Page 8: ...8 V3 205 Dispensing System Owner s Manual Section 2 General Information...

Page 9: ...it under a standard minimum 24 wide base cabinet section The system has been designed for operation at ambient temperatures up to 90 F Dispensing Specifications Description Specification Chilled still...

Page 10: ...ooler Carbonator Specifications Description Specification Width 14 7 Height 18 5 Depth 17 0 Weight 72 6 lbs Voltage 110 120 VAC 60 Hz Amperage 8A Dispenser Head Specifications Description Requirements...

Page 11: ...sure 50 PSI Minimum Water Flow 80 gallons per hour IMPORTANT__________________________ The Vivreau V3 205 Dispensing System incorporates back flow prevention Any additional back flow devices required...

Page 12: ...les cut in a standard door panel Cut out detail for the VIVREAU grille shown in a 23 5 24 wide door Side Ventilation Ventilation grilles cut in the side of a standard 24 cabinet The grilles may be fit...

Page 13: ...h Dispenser Handle UP when full Dispensing Chilled Sparkling Water The Dispenser Handles should be fully opened when filling and fully closed when filling is complete IMPORTANT________________________...

Page 14: ...er is FULL a Red LED will illuminate and the unit will beep alerting you to empty the Drip Tray Container located just inside the cabinet front door or below the Dispensing System AFTER DAILY USE At t...

Page 15: ...tizer in accordance with Local Health Codes ALWAYS sanitize Bottles in dishwasher ALWAYS place Bottles upside down in Bottle Washing Rack Bottle Storage ALWAYS leave Caps attached to Bottle during san...

Page 16: ...16 V3 205 Dispensing System Owner s Manual Section 5 Operation...

Page 17: ...TANT__________________________ Record all yearly inspections IMPORTANT__________________________ Contact the factory the factory representative or an authorized service agent to perform maintenance an...

Page 18: ...ainless steel polishing cleaner as a final step to daily cleaning If signs of breakdown appear restore the stainless steel surface First thoroughly clean rinse and dry the surface Then on a daily basi...

Page 19: ...s for ease of cleaning and sanitizing IMPORTANT__________________________ The Nozzles must be cleaned separately in Sanitizing Solution WARNING Wear protective gloves when handling Sanitizing Solution...

Page 20: ...g Fins Never place objects in front of the Cooling Fins Clean the Cooling Fins with a suitable brush or with a vacuum cleaner Degrease with a soft cloth sprayed with degreaser CAUTION Never spray degr...

Page 21: ...le Periods If the V3 205 Dispensing System will be idle for more than 3 days Unplug the unit Close the Water Supply Valve Clean the following with antibacterial wipes and disinfectant spray Dispensing...

Page 22: ...followed properly Follow the procedures listed below in the event of a leak WATER Disconnect the Water Dispenser from the power supply Disconnect the water supply by closing the Water Supply Valve Cle...

Page 23: ...oming out check theWater Supply Valve or power If nothing is coming out check CO2 tank and change if needed LED DISPLAY LED Display Panel Location and Lights POWER Make sure unit is plugged in CHANGE...

Page 24: ...24 V3 205 Dispensing System Owner s Manual Section 7 Troubleshooting NOTES...

Page 25: ...V3 205 Dispensing System Owner s Manual 25 Section 7 Troubleshooting NOTES...

Page 26: ...26 V3 205 Dispensing System Owner s Manual Section 7 Troubleshooting NOTES...

Page 27: ...V3 205 Dispensing System Owner s Manual 27...

Page 28: ...ew Zealand Tel 64 9 377 8621 VIVREAU Ireland 44 0 845 674 9655 email info vivreau ie VIVREAU USA 1 877 999 1044 email infousa vivreau com VIVREAU South Africa 27 21 671 6306 email info vivreau co za T...

Reviews: