VIVOTEK
User's Manual - 299
© 2019 VIVOTEK INC. All Right Reserved
170
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
<product
dependent>
can't select it.
- (unchanged) : UI keeps the status as
before and
user can't change it.
- (hidden) : UI is hidden.
- (fixed) : UI is fixed to one selection or
value.
- (ranged) : UI is fixed to multiple
selections or values.
- (enabled) : UI is checked.
- (notsupport) : the affected function
is not available.
"Affect API name" can be described in
hierarchy, such as
"exposurewin.mode.blc:disabled:"
which means blc exposure window is
disabled. API name can be one word
as well, such as
"exposurelevel:fixed:6" which means
exposurelevel is fixed to level 6.
"Description" can be a nonnegative
integer or string or NULL.
"-" means no feature is affected.
* Only available when manual is listed
in "capability_image_c<0~(n-1)>_
exposure_modetype" and
"capability_image_c<0~(n-1)>_
exposure_mode" is 1.
* We support this parameter when
the version number (httpversion) is
equal or greater than 0302a.
exposure_levelrange
-,
"0,12"
0/7
Available range for
"videoin_c<0~(n-1)>_exposurelevel"
* When "exposure_mode"=0, this
value must be set to "-".
* Only available when
© 2019 VIVOTEK INC. All Right Reserved
171
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
"capability_image_c<0~(n-1)>_
exposure_mode" is 1.
exposure_winmode
auto,
custom,
blc,
hlc,
center,
-
<product
dependent>
0/7
Available options for
"exposurewin_c<0~(n-1)>_mode"
* "-" means group: exposurewin is not
supported.
* When exposure_mode="0", this
value must be set to "-".
* Only available when
"capability_image_c<0~(n-1)>_
exposure_mode" is 1.
exposure_meteringm
ode
auto,
blc,
hlc
<product
dependent>
0/7
Available options for
"videoin_c<0~(n-1)>_meteringmode"
* Only available when
"capability_image_c<0~(n-1)>_
exposure_mode" is 1.
exposure_hlcmode_s
upportwindow
<boolean>
0/7
Indicate whether to support exposure
window in hlc mode.
* Only available when
"capability_image_c<0~(n-1)>_
exposure_mode" is 1 and hlc is listed
in "capability_image_c<0~(n-1)>_
exposure_winmode".
exposure_hlcmode_af
fect
-,
or others
<x>: nonnegative
integer
<product
dependent>
0/7
When hlc mode is enabled, some
features may become malfunction or
be forced to a given value. The
affected functions are list here.
The format is "Affect API
name":"Policy":"Description"
"Policy" can be categorized into
following groups:
- (disabled) : UI turns grey and users
can't select it.
- (unchanged) : UI keeps the status as
before and
user can't change it.
Summary of Contents for MS9321-EHV