VIVOTEK
232 - User's Manual
ircutsensitivity_type
<string>
0/7
Indicate the cgi interface of
"ircutcontrol_sensitivity".
"options"
: the value of
"ircutcontrol_sensitivity" parameter is "low,
normal,high".
"normalize"
: the value of
"ircutcontrol_sensitivity" parameter is "1~100"
"-"
:not support
* Only available when
"capability_daynight_c<0~(n-1)>_support" is
1.
* We support this parameter when the version
number (httpversion) is equal or greater than
0302a.
ircutsensitivity_supportlevel 0,
<positive integer>
0/7
The value indicate the support strength level of
ircutsensitivity.
* Only available when
"capability_daynight_c<0~(n-1)>_support" is 1
and
"capability_daynight_c<0~(n-1)>_ircutsensitivi
ty_type" is not "-".
* We support this parameter when the version
number (httpversion) is equal or greater than
0302a.
extled_interface do,irring
<product dependent>
0/7
The device interface of external IR led:
"do":
digital output
"irring":
IR ring
* Only available when
"capability_daynight_c<0~(n-1)>_externalir" is
1
* We support this parameter when the version
number (httpversion) is equal or greater than
0304a.