62
patrolseq
string[120]
<blank>
1/4
The patrol sequence of ePTZ. All the
patrol position indexes will be
separated by ","
patroldwelling
string[160] <blank> 1/4
The dwelling time (unit: second) of
each patrol point, separated by “,”.
preset_i<0~19>_name
string[40]
<blank>
1/7
Name of ePTZ preset.
(It should be set by ePreset.cgi rather
than by setparam.cgi.)
preset_i<0~19>_pos <coordinate> <blank>
1/7
Left-top corner coordinate of the
preset.
(It should be set by ePreset.cgi rather
than by setparam.cgi.)
preset_i<0~19>_size
<window size> <blank>
1/7
Width and height of the preset.
(It should be set by ePreset.cgi rather
than by setparam.cgi.)
7.33 Exposure window setting per channel
Group:
exposurewin_c<0~(n-1)>
for n channel products
NAME
VALUE
DEFAULT
SECURITY
(get/set)
DESCRIPTION
mode
auto, custom,
blc
auto
4/4
The mode indicates
how to decide the
exposure.
auto: Use full view
as the only one
exposure window.
custom: Use
inclusive and
exclusive window.
blc: Use BLC.
win_i<0~9>_enable
<boolean>
0
4/4
Enable or disable the
window.
win_i<0~9>_policy
0~1
0
4/4
0: Indicate
exclusive.
1: Indicate inclusive.
win_i<0~9>_home
<coordinate>
110,90
4/4
Left-top corner
coordinate of the