Vivotek Camate CM80 Series Installation Manual Download Page 1

Installation Guide

CM80 Series

Vari-Angle IR Illuminator

Rev. 1.1

QIG Part no.: 625040201G

Summary of Contents for Camate CM80 Series

Page 1: ...Installation Guide CM80 Series Vari Angle IR Illuminator Rev 1 1 QIG Part no 625040201G ...

Page 2: ...fects WARNING The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 2 5 m is not expected The external flexible cable or cord of this luminaire cannot be replaced if the cord is damaged the luminaire shall be destroyed The light source of this luminaire is not replaceable when the light source reaches its end of life the whole luminaire shall be ...

Page 3: ...ting temperature Do not touch the Illuminator during a lightning storm IMPORTANT Class III luminaires Do not stare at the operating light source This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable re...

Page 4: ...4 160mm 6 3 220mm 8 7 73mm 2 9 103 8mm 4 1 134 6mm 5 3 61 5mm 2 4 164 6mm 6 5 59 5mm 2 3 43mm 1 7 43mm 1 7 59mm 2 3 32mm 1 3 Mechanical Drawings 134 M6x1 4 64 29 3 8 2 30 82 Standard Small U bracket ...

Page 5: ...or external camera housing U bracket Waterproof cover for angle selector Optional mounting points for U bracket Light sensor Combo cable Dehumidifier membrane Reserved Mounting holes Unit Weight 2 1KG Max Project Area 34684 7mm2 160mm 6 3 220mm 8 7 ...

Page 6: ...rientation Use the included allen wrench to attach and adjust the U bracket to your needs at the installation site It is highly recommended that the illuminator should be installed at a position higher than 3 meters from the ground IMPORTANT ...

Page 7: ...de of the allen wrench to turn the beam angle to an estimated illumination distance e g 200 meters See the tables on the next page for how to do it You may forget your current beam angle configuration In this case turn many full circles clockwise until the rotation resistance is felt returns to the widest angle reaches its mechanical stops and then turn the selector counter clockwise according to ...

Page 8: ...29 210 108 6 297 0 153 6 363 7 188 1 3 27 221 106 1 312 5 150 1 382 8 183 8 4 20 280 98 7 396 0 139 6 485 0 171 0 Counter clockwide Narrower Clockwide Wider The factory default for the beam angle selector is always at the Widest angle When you turn the selector many rounds to its widest or the narrowest position a rotation resistance can be felt That means the mechanical stop is reached and you sh...

Page 9: ... 155 1 164 5 190 0 6 55 100 104 1 141 4 147 2 173 2 180 3 7 52 105 102 4 148 5 144 8 181 9 177 4 8 50 109 101 7 154 1 143 8 188 8 176 1 9 45 115 95 3 162 6 134 7 199 2 165 0 10 40 120 87 4 169 7 123 5 207 8 151 3 CM80I8 90120 Rotate direction Full circle Beam angle Single mount Double mount Triple mount Distance m Width m Distance m Width m Distance m Width m 0 120 60 207 8 84 9 293 9 103 9 360 0 ...

Page 10: ...10 Select a position at the installation site e g under a hanging roof You can use the alignment sticker and start drilling a hole on the roof Apply the included grip sticker to the U bracket ...

Page 11: ...chor Hammer the anchor in user supplied M6 anchors are recommended Secure the U bracket to it such as securing it using the bolt on a threaded pole Secure the illuminator to bracket using the hex socket screws ...

Page 12: ...or to precisely match the illuminated area with the camera s field of view If necessary adjust the beam angle again Turn the illuminator toward the FOV of the partner camera shift the tilt angle and then tighten the screw and the rear cover to secure the illuminator ...

Page 13: ...ontrol Dry contact Logic level 1 Open LED off Logic level 0 Close to GND LED on Wet contact Logic level 1 4V 40 V LED off Logic level 0 0 8V MAX LED on DI Yellow 26AWG Ground DO Purple 26AWG Light sensor status output 1 Open Day 2 Short Night 300 lux for IR ON DO Blue 26AWG Ground RS485 Orange 26AWG RS485 interface control RS485 Brown 26AWG Cable Pinouts ...

Page 14: ... Green Yellow wires This mode means that CaMate illuminator On Off control is triggered by camera or other alarm system User can decide using the appropriate dry wet contacts depending on wiring condition DI Green TTL voltage DI Yellow TTL voltage GND Dry contact Logic level 1 Open LED off Logic level 0 Close to GND LED on Wet contact Logic level 1 4V 40 V LED off Logic level 0 0 8V MAX LED on ...

Page 15: ...rent must be under 100mA DO Bule GND Light sensor status output 1 Open Day 2 Short Night lower than 300 lux for IR to turn ON Stand alone illuminator mode This mode means that the illuminator s On Off control is triggered by its light sensor in the case the default wiring is connecting the green wire with purple wire Some cameras have related settings that need the inter connection with the illumi...