4-2-9. PoE Auto Checking
Function name:
Auto Checking
Function description:
The function is using for PD auto checking. It can allow user to control the PoE
function by using the ping command, in order to turn on or off any PD which
connect with port assign.
Fig. 4-14
Parameter description:
Ping Check:
To scroll and select the Enable or Disable Ping Check function.
Port No.:
To display the Port Index, the maximum is 24.
Ping IP Address:
To set up the PD’s IP address which you need to check it is alive.
Interval Time:
To set up the spacing interval time to do ping check, the default value is
30 seconds. The available range is 10 to 120 seconds.
Retry Time:
To set up the number of times for switch to check PD is alive. The default
is 3. The available range is 1 to 5.
Failure Log:
To display the PD’s Ping result and log. Note down “Ping Check” a result
of movement after starting. The error means switch to ping the PD is