VIVOTEK
User's Manual - 175
triggerstatus String[40]
trigger
6/6
The status for event trigger.
exttriggerstatus String[40]
<blank>
6/6
The status for event trigger.
exttriggerstatus1 String[40]
<blank>
6/6
The status for event trigger.
exttriggerstatus2
String[40] <blank> 6/6
exttriggerstatus2
di
0~3
1
6/6
Indicate the source id of di trigger.
This field is required when trigger
condition is “di”.
One bit represents one digital input. The
LSB indicates DI 0.
mdwin
0~7
0
6/6
Indicate the source window id of motion
detection.
This field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows, set mdwin as 5.
mdwin0
0~7
0
6/6
Similar to mdwin. The parameter takes
effect when profile 1 of motion detection
is enabled.
vi
0~7
0
6/6
Indicate the source id of vi trigger.
This field is required when trigger
condition is “vi”.
One bit represents one digital input. The
LSB indicates VI 0.
valevel
0,1
0
6/6
Select audio detection event.
0: not select
1: select
valevel0
0,1
0
6/6
Select audio detection profile event.
0: not select
1: select
inter
1~999
1
6/6
Interval of snapshots in minutes.
This field is used when trigger condition
is “seq”.