General
Power Supply
DC 24V
2.71A
Power Consumption
48W (Max)
Temperature
-10 ~ +40
℃
Reference Humidity
10% ~ 90%
Dimension (W*H*D)
437 x 44 x 235 mm (1U high, full rack wide)
Weight
2.0Kg
35
Page 1: ...VL120012 4K HDBaseT 4x4 Matrix Switcher User Manual 1 ...
Page 2: ... of this publication may be copied or reproduced without the prior written consent of EET Europarts A S FCC Statement This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications It has been tested and found to comply with the limits for a Class B digital device pursuant...
Page 3: ... or install this product near water Do not put any heavy items on the extension cable in case of extrusion Do not remove the housing of the device as opening or removing housing may expose you to dangerous voltage or other hazards Install the device in a place with fine ventilation to avoid damage caused by overheat Keep the module away from liquids Spillage into the housing may result in fire ele...
Page 4: ...rations 12 4 1 Front Panel Button Control 13 4 1 1 Switching I O connection 13 4 1 2 EDID Management 13 4 1 3 Inquiry 15 4 1 4 Clear operation 16 4 2 IR Control 16 4 2 1 Usage of IR Remote 16 4 2 2 Force Carrier 17 4 2 3 Control Far end Device locally 17 4 2 4 Control Local Device Remotely 18 4 3 RS232 Control 19 4 3 1 Connection with RS232 Communication Port 19 4 3 2 Control through 9 pin RS232 p...
Page 5: ...her 4 4 TCP IP Control 28 4 4 1 Control Modes 28 4 4 2 GUI for TCP IP control 30 4 4 3 GUI Update 32 4 5 Firmware Update via USB 33 5 Specification 34 6 Panel Drawing 35 7 Troubleshooting Maintenance 37 8 After sales Service 39 5 ...
Page 6: ...via HDMI outputs HDBaseT outputs and the audio output sockets The unit also supports bi directional RS232 IR control 1 2 Features Support HDMI 1 4 HDCP2 2 and compliant with lower standards capable to transmit 4Kx2K 60Hz 1080p 3D Support manual HDCP management and auto detecting Transmit 4Kx2K signal for 8m via HDMI port 40m via HDBT port Audio source selectable via RS232 command 4 HDBaseT outputs...
Page 7: ... 6 x Screws 1 x RS232 cable 1 x IR Receiver 4 x Plastic cushions 4 x Black Screws 1 x IR remote 1 x Power Adapter DC 24V 2 71A 8 x Pluggable Terminal Blocks 1 x User manual Notes Confirm if the product and the accessories are all included if not please contact with the dealers 7 ...
Page 8: ...o 4 Output 1 2 support synchronous local HDMI output EDID Invoking mode press and hold EDID button for 3 seconds or more to enter this mode in this mode button 1 2 are used to switch to the previous next EDID data Function buttons ALL Select all inputs outputs EDID management button Enable input port to manually capture and learn the EDID data of output devices CLEAR Withdraw an operation like swi...
Page 9: ...vers and all IR signals can be switched synchronously with the AV signal or separately switched OUTPUTS a IR IN Connect with IR receiver fixed IR input for the output cannot be switched separately It makes up an IR bi directional transmission with the IR OUT on the corresponding HDBaseT receiver b COAX HDMI de embedded digital audio output c RS232 Serial port to communicate with the RS232 port on ...
Page 10: ...iver use the IR remote to control VL120012 TCP IP TCP IP port for unit control RS232 Serial port for unit control 9 pin female connector connects with control device such as a PC Power Indicator Illuminate red when powered on DC 24V Connect with DC 24V power adaptor GROUND Connect to grounding make the unit ground well Note Pictures shown in this manual are for reference only different model and s...
Page 11: ...nference system television education and bank securities institutions etc 3 2 Usage Precautions 1 System should be installed in a clean environment and has a prop temperature and humidity 2 All of the power switches plugs sockets and power cords should be insulated and safe 3 All devices should be connected before power on 3 3 Connection Diagram VCR STB DVD VL120001R PC IR Emitter Speaker Projecto...
Page 12: ...emote via its built in IR sensor or through external IR receiver connected to the IR IN IR EYE IR ALL IN port The IR signal can be transmitted bi directionally between VL120012 and far end receivers 8 Connect a DC 24V power adapter and the VL120012 Note 1 Connect HDBT ports of VL120012 and far end receiver with straight through cable 2 IR receivers connected to IR IN IR ALL IN should be with carri...
Page 13: ...ponding IR OUT will be switched synchronously 2 To convert an input to several outputs Operation input output output ENTER Example Switch input 2 to output 2 4 3 To convert an input to all outputs Operation input ALL ENTER Example Convert input 1 to all outputs Note Indicators of the pressed buttons will blink green for three times if the conversion is done then it will be off If the conversion fa...
Page 14: ...five types of embedded EDID data The chart below illustrates the detailed information of the embedded EDID data No EDID Data 1 1080P 2D 2CH 2 1080P 3D 2CH 3 1080P 2D Multichannel 4 1080P 3D Multichannel 5 3840x2160 2D 30Hz Press and hold EDID for 3 seconds to enter EDID invoking mode in this mode use output buttons 1 2 to switch among the 5 embedded EDID data Then press ENTER to confirm invoking F...
Page 15: ...tion Items Example Description Check the connection status of inputs Y means the corresponding port is connected with input device N means not Check the connection status of outputs Y means the corresponding port is connected with output device N means not Correspondence between inputs and outputs Shows the correspondence between the 4 inputs and 4 outputs Check if the input is with HDCP Y means t...
Page 16: ...he VL120012 has some functions as follows 1 Control far end output device from local 2 Control local input output device remotely 3 Control the VL120012 locally remotely 4 2 1 Usage of IR Remote Standby button press it to enter exit standby mode Input channels range from 1 4 buttons 5 8 are not available corresponding IR signal switched synchronously when switching input channels Menu buttons ALL ...
Page 17: ...R signal can be transferred to IR OUT port 4 2 3 Control Far end Device locally Connect an IR receiver to IR IN IR ALL IN on the switcher and use the IR Remote of far end device to control the device locally 1 to 1 through IR IN Connect an IR receiver with IR carrier to the IR IN port of VL120012 users can control far end output displayer via its IR remote from local In that case the IR signal is ...
Page 18: ...nd HDBT receiver and an IR Emitter to IR OUT port of the switcher Use the IR Remote of local source to control the device remotely See below Control local device from remote Note Send command 0901 to enter infrared carrier enforcing mode if the IR Receiver connected to IR IN of the receiver is not with carrier Multiple to Multiple IR Matrix The 4 IR OUT ports and the 4 IR IN ports on the far end r...
Page 19: ...placed at IR receiving area of output device or VL120012 itself x2 Corresponding to the zone receive IR signal from HDBaseT receiver with IR IN port connects with IR receiver number of VL120012 Example Send command 3R2 to transfer IR signal received from zone 2 to IR OUT port 3 4 3 RS232 Control 4 3 1 Connection with RS232 Communication Port Except the front control panel the VL120012 can be contr...
Page 20: ... the figure below Control the switcher 3rd party Device through 9 pin female RS232 port Control the switcher send RS232 commands directly Control 3rd party send command Y X Refer to for detailed information 4 3 3 Control through 3 pin RS232 port Control 3rd party device from local Connect the RS232 3 pin pluggable terminal block port in any zone to PC and connect the controlled RS232 device 3rd pa...
Page 21: ... 4 3 4 Installation uninstallation of RS232 Control Software Installation Copy the control software file to the computer connected with VL120012 Uninstallation Delete all the control software files in corresponding file path 4 3 5 Basic Settings Firstly connect VL120012 with an input device and an output device Then connect it with a computer which is installed with RS232 control software Double c...
Page 22: ...4 3 6 RS232 Communication Commands Note 1 Please disconnect all the twisted pairs before sending command EDIDUpgrade X 2 In above commands and are symbols for easy reading and do not need to be typed in actual operation 3 Please remember to end the commands with the ending symbols and Parameter Configuration area Monitoring area indicates whether the command sent works Command Sending area Paramet...
Page 23: ...02 IR 01 02 AV 04 04 IR 04 04 Undo To cancel the previous operation Undo Ok Out 01 02 03 04 In 01 01 01 01 Operation Commands x All Transfer signals from the input channel x to all output channels X To All X 01 04 All Transfer all input signals to the corresponding output channels respectively like 1 1 2 2 All Through All Switch off all the output channels All Closed x Transfer signals from the in...
Page 24: ...FY Y 0 9 Recall Y Recall the preset command Y Recall From FY Y 0 9 Clear Y Clear the preset command Y Clear FY Y 0 9 PWON Work in normal mode PWON PWOFF Enter into standby mode and cut off the power supply to HDBaseT receivers PWOFF STANDBY Enter into standby mode Do not cut off the power supply to HDBaseT receivers press other buttons or send other commands to start STANDBY Y X Z HDCP management ...
Page 25: ... to all HDBaseT receivers to control all far end devices c Y A B C or D d Y E F G or H For items c or d send this command it will be saved to the matrix switcher but taken without action to corresponding HDBaseT receiver And its command function will be effective almost at the same time when you send the command PWON for item c or PWOFF for item d Note A E are for port 1 B F are for port 2 C G are...
Page 26: ...de EDID data via the RS232 port x is the input port when the value of X is 9 it means to upgrade all input ports When the switcher receives the command it will show a message to prompt you to send EDID file bin file Operations will be canceled after 10 seconds Please cut off all connections of HDBaseT ports Please send the EDID file EDID x y Set the EDID data of input port x to built in EDID No y ...
Page 27: ...nd sent by port 4 when PWON Port 4 data when PWON 9955 Check the command sent by port 1 when PWOFF Port 1 data when PWOFF 9956 Check the command sent by port 2 when PWOFF Port 2 data when PWOFF 9957 Check the command sent by port 3 when PWOFF Port 3 data when PWOFF 9958 Check the command sent by port 4 when PWOFF Port 4 data when PWOFF 9961 Check the system locking status System Locked Unlock 9962...
Page 28: ...l VL120012 boasts option TCP IP port for IP control Default settings IP 192 168 0 178 Subnet Mast 255 255 255 0 Gateway 192 168 0 1 Serial Port 4001 IP gateway can be changed as you need Serial Port cannot be changed Connect the Ethernet port of control device and TCP IP port of VL120012 and set same network segment for the 2 devices users are able to control the device via web based GUI or design...
Page 29: ...able to control VL120012 Follow these steps to connect the devices Step1 Connect the TCP IP port of the VL120012 to Ethernet port of PC with twisted pair Step2 Set the PC s network segment to the same as the VL120012 N s Do please remember the PC s original network segment Step3 Set the VL120012 s network segment to the same as the router Router Internet PC TCP IP Port Same network segment as the ...
Page 30: ...cators Type 192 168 0 178 in your browser it will enter the log in interface shown as below There are 2 selectable usernames admin default password admin and user default password user Log in as admin can access more configuration interfaces than user Enter username and the right password Here is a brief introduction to the interfaces Main Interface shown after logging in provide intuitive I O con...
Page 31: ...ential settings front panel lock and GUI version If there is any modification press Save to restore the settings or press Cancel to withdraw Interface Set title bar label LCD readout and button labels press Save to save the settings Configuration Set HDCP Cmpliance status for every input and manage EDID See the screenshot below 31 ...
Page 32: ...e only 4 4 3 GUI Update GUI for VL120012 supports online update in http 192 168 0 178 100 Type the username and password the same as the GUI log in settings modified password will be available only after rebooting to log in the configuration interface After that click Administration at the source menu to get to Upload Program as shown below 32 ...
Page 33: ... Copy the upgrade software and the latest upgrade file bin to PC Step2 Connect the USB ports of VL120012 and the PC via USB cable Step3 Double click the update software icon see as below It will enter the upgrade interface shown as below Step4 Click Connect USB Step5 Click Open to load the upgrade file then click Updata to start firmware upgrading Note To ensure available control the COM number of...
Page 34: ...t In built EDID data and manual EDID management HDCP Supports HDCP 2 2 auto and manual HDCP management Audio General Output Signal Stereo audio Digital audio Output Connector 4 3 pin pluggable terminal blocks 4 Coax RCA Stereo Output Earphone output distortion 0 1 32Ω 70mW 1KHz 0 1 16Ω 105mW 1KHz support PCM Coax Output Supports PCM Dolby Digital DTS DTS HD Frequency Response 20Hz 20KHz Control Pa...
Page 35: ...General Power Supply DC 24V 2 71A Power Consumption 48W Max Temperature 10 40 Reference Humidity 10 90 Dimension W H D 437 x 44 x 235 mm 1U high full rack wide Weight 2 0Kg 35 ...
Page 36: ...436 40 mm 23 10 mm 44 00 mm 31 80 mm RS232 IR EYE TCP IP HDMI INPUTS IR OUT 1 2 3 4 1 2 3 4 OUTPUTS HDMI AUDIO HDBaseT HDMI 2 3 4 L R AUDIO L R AUDIO L R AUDIO L R Tx Rx Tx Rx Tx Rx IR IN 1 IR IN IR IN IR IN IR ALL IN COAX HDBaseT HDBaseT HDBaseT DC 24V COAX COAX COAX Tx Rx HDCP2 2 36 ...
Page 37: ...us in GUI The display doesn t support the input resolution Switch for another input source or enable the display to learn the EDID data of the input Cannot control the device via front panel buttons Front panel buttons are locked Send command Unlock or select unlock in GUI interface to unlock Cannot control the device via IR remote The battery has run off Change for new battery The IR remote is br...
Page 38: ...tion Check to ensure the connection between the control device and the unit Wrong RS232 communication parameters Type in correct RS232 communication parameters Baud rate 9600 Data bit 8 Stop bit 1 Parity bit none Broken RS232 port Send it to authorized dealer for checking Static becomes stronger when connecting the video connectors Bad grounding Check the grounding and make sure it is connected we...
Page 39: ...roduct Damage deterioration or malfunction caused by Normal wear and tear Use of supplies or parts not meeting our specifications No certificate or invoice as the proof of warranty The product model showed on the warranty card does not match with the model of the product for repairing or had been altered Damage caused by force majeure Other causes which does not relate to a product defect Delivery...