Vivo DESK-V103EW Instruction Manual Download Page 3

3

CODE        DESCRIPTION 

                              RESOLUTION 

 

E02

  

Uneven leg height 

 

 

 

E04 

 

Control panel connection error          

E05

  

Collision detected    

        

E06

  

Electrical problem   

           

E08

  

Uneven desktop  

 

           

E11

  

Motor 1 not connected                      

E12/E22

   Abnormal electrical current                 

E13             

Motor power wire damaged                

E14

  

Motor sensor wire damaged               

E15 

 

Short circuit in motor 1                        

E16/E26

   Motor problem                                          

E17

  

Motor 1 running in reverse

E18/E28

   Overload 

E21

  

Motor 2 not connected 

E23 

 

Motor power wire damaged

E24

  

Motor sensor wire damaged 

E25

  

Short circuit in motor 2 

E27 

 

Motor 2 running in reverse 

E42

  

Memory function failure 

E43

  

Collision sensor failure

Reset the desk

Check the connection then reconnect desk power

Release button and clear obstructions

Replace the control unit

Reset the desk and ensure weight is evenly distributed

Check connection to control unit (M1)

Replace the control unit

Replace the motor cable (M1)

Replace the motor cable (M1)

Replace the motor (M1)

Reset the desk

Replace the motor cable (M1)

Remove excess weight from the desk

Check connection to control unit (M2)

Replace the motor cable (M2)

Replace the motor cable (M2)

Replace the motor (M2)

Replace the motor cable (M2)

Replace the control unit
Replace the control unit

HOT Troubleshooting

The system is overheating. Allow 

your desk to cool down and remain 

idle for approximately 18 minutes.

bêO

1

CUSTOM PROGRAMMING

To enter the custom programming menu, press and hold “M” and “T” together for 5 seconds. The 

controller will beep once and display “S-1”. If no action is taken for more than 10 seconds, the 

controller will automatically exit the menu. Unsaved settings may be canceled by pressing “T”.  The 

following instructions assume the controller is in the “S-1” state. 

Minimum & Maximum Height Settings

To set a minimum height limit 

1. Press “M” once, then press the up or down arrow to set your desired min. height.

2. Press “M” to save. “L-S” will be displayed if successfully saved, or “L-F” shows if failed.

Note: Default min. height is 62cm (24.4”), and the adjustable range is 62-118cm (24.4”~46.4”).

To set a maximum height limit

1. Press the up or down arrows until “S-2” is displayed.

2. Press “M” once, then press the up or down arrow to set your desired max. height.

3. Press “M” to save. “H-S” will be displayed if successfully saved, or “H-F” shows if failed.

Note: Default max. height is 128cm (50.4”), and the adjustable range is 72-128cm (28.3”~50.4”).

Adjust the Anti-Collision Sensitivity (Current Sensor)

To set collision sensitivity for upward movement:

1. Press the up or down arrows until “S-3” is displayed.

2. Press “M” once, then press the up or down arrow to change the sensitivity level.

3. Press “M” to save. “S-S” will be displayed if successfully saved, or “S-F” shows if failed.

Note: Default sensitivity is 4, and the adjustable range is 0-8. (0: off, 8: maximum)

To set a downwards current sensitivity

1. Press the up or down arrows until “S-4” is displayed.

2. Press “M” once, then press the up or down arrow to change the sensitivity level.

3. Press “M” to save. “S-S” will be displayed if successfully saved, or “S-F” shows if failed.

Note: Default sensitivity is 4, and the adjustable range is 0-8. (0: off, 8: maximum)

To set collision sensitivity for the gyro sensor

1. Press the up or down arrows until “S-5” is displayed.

2. Press “M” once, then press the up or down arrow to change the sensitivity level.

3. Press “M” to save. “S-S” will be displayed if successfully saved, or “S-F” shows if failed.

Note: Default sensitivity is 4, and the adjustable range is 0-8. (0: off, 8: maximum)

Summary of Contents for DESK-V103EW

Page 1: ...evice or follow the link for helpful videos and specifications related to this product https vivo us com products desk v103ew SKU DESK V103EW Controller 2 1 3 help vivo us com www vivo us com 309 278 5303 Chat live with an agent GET IN TOUCH Monday Friday from 7 00am 7 00pm CST ...

Page 2: ...nce the timer setting has expired 5 beeps the unit s timer is canceled To deactivate the timer press T five times or until the current height is displayed and the light in the upper right corner is turned off Memory Setting To store a certain height in the controller s memory first press M The letter S will be displayed Now press 1 2 or 3 within five seconds to store the current height in memory E...

Page 3: ...ollowing instructions assume the controller is in the S 1 state Minimum Maximum Height Settings To set a minimum height limit 1 Press M once then press the up or down arrow to set your desired min height 2 Press M to save L S will be displayed if successfully saved or L F shows if failed Note Default min height is 62cm 24 4 and the adjustable range is 62 118cm 24 4 46 4 To set a maximum height lim...

Page 4: ... F shows if failed When screen lock is enabled the display will read after resting 60 seconds Press and hold M for 3 seconds to unlock Screen may be locked before 60 seconds by holding M again for 3 seconds To Save the Customized Settings at one time After adjusting one setting press T to go back and enter another setting Once finished press M to save all settings To Reset the Customized Settings ...

Reviews: