Ultra Short Throw Lens – Installation Guide 
 

 

6

 

c. Enter OSD menu then select Lens type option on ALIGNMENT page, press Enter or 

 button to choose UST Lens 

option. The projector can move the lens to initial workable position for Ultra Short Throw lens automatically after 
performing Center Lens function as following step. 

 

 

d. Perform Center Lens function to calibrate projection lens by the control button or OSD menu, the calibration can get 

more precise lens adjustment and move the lens to workable position automatically for the projection.   
 

Note:  

  Setting Lens type option to UST Lens will change the default lens position after performing Center Lens function, 

please select UST Lens in this option if using ultra short throw lens. Otherwise, please select non-UST lens. 
Improper setting may limit the lens shift range and move the lens to incorrect default position after performing 
Center Lens function. 

 

6.  .Fine tune the projected image position 

The initial position can get best projection performance, some of Vivitek projectors may offers wider adjustable shift 
range for flexibility in installation, the adjustable shift range are 

±

5% in horizontal shift, +7% for moving up, -3% for 

moving down. Please tune the lens shift to desired position by Lens Shift buttons on the control panel or remote 
control, and check the projection performance. 

 

 

 

Note: 

  Make sure to loosen the screws at the joints of support kits before fine tuning the lens position or performing 

Center Lens function, improper operation may cause to malfunctioned Lens shift or damage the projection lens. 

 

7.  Attach the metal arm to the bracket on the projection lens 

Use two screws to attach the metals arm to the bracket on the projection lens as below figure, the screws shall be kept 
loose till you finish all of necessary lens shift adjustment. 
 

 

 

 

 

Summary of Contents for DU8090Z

Page 1: ... 1 Table of Content Important Notice 2 Packing Check List 2 Projection Lens Overview 3 Installing the Projection Lens 4 Projection Distance and Size 9 Projection Lens Specifications 10 Projection Lens Dimensions 10 About the VIVITEK Support 11 ...

Page 2: ...or Lens cleaning wipes to wipe away dirt or dust adhered on the lens Do not use the cloth containing oil dust or water for cleaning Once dust and dirt adhered on the lens surface please clean the glass with lens cleaning wipe Keep all the original packing material even you finish the installation the packing material may be used for avoiding damage during transportation Packing Check List Item Par...

Page 3: ...d melt it it may raise safety issue or damage the projector One protective film is attached on projection light outlet for avoiding scratch or dust on this protection surface please remove the protective film before tuning on the projector Improper operation may cause to the projective film Projection light outlet Mounting bracket Screw holes x 2 Guide Pin x 2 Motor for Focus Adjustment Motor for ...

Page 4: ...ion improper operation may cause to malfunctioned Lens shift or damage the projection lens Make sure Lens type setting is changed to Non UST Lens from OSD menu once you change to other projection lens The default lens position of Ultra short Throw Lens UST Lens is different to other zoom lenses the setting may limit the lens shift range and move the lens to different initial lens position after yo...

Page 5: ...efore installing the lens on the projector recommend to place the projector on a table and the front of the projector is aligned with the edge of the table This can help you installing the projection lens more convenient 5 Adjust the projecting position of Lens a Plunge in the power cable b Turn on the AC switch then turn the projector on by power button CAUTION Make sure the projective film on th...

Page 6: ...s shift range and move the lens to incorrect default position after performing Center Lens function 6 Fine tune the projected image position The initial position can get best projection performance some of Vivitek projectors may offers wider adjustable shift range for flexibility in installation the adjustable shift range are 5 in horizontal shift 7 for moving up 3 for moving down Please tune the ...

Page 7: ...allation Ceiling Installation Note The projection lens is fixed firmly after you tighten the screws make sure to loosen all of the screws on the support kits before operating Lens Shift or Lens Center function Some of Vivitek projectors may offer wider adjustable shift range for flexibility in installation the initial position by Center Lens can get best projected performance please check the perf...

Page 8: ...screen and place the projector in parallel with the projector The image may be distorted if the projection screen is not flat or not in parallel with the rear of projector Check if the support kit is installed properly if the projection image is not clear after adjusting the focus and focus plane 10 Lock the Lens control If your projector is with Lens Lock function on OSD recommend to lock the Len...

Page 9: ...08 0 13 5 01 2 47 97 25 1 66 65 21 0 84 33 22 130 2 81 110 82 1 76 69 37 1 08 42 36 0 79 31 06 0 20 7 99 2 66 104 90 1 78 70 19 0 90 35 53 140 3 03 119 33 1 90 74 69 1 15 45 34 0 86 34 04 0 28 10 97 2 86 112 53 1 91 75 17 0 96 37 83 150 3 25 127 83 2 03 80 02 1 23 48 32 0 94 37 02 0 35 13 95 3 05 120 15 2 04 80 14 1 02 40 13 160 3 46 136 36 2 17 85 36 1 30 51 30 1 02 40 00 0 43 16 93 3 25 127 81 2...

Page 10: ...1 2 08 81 71 1 49 58 64 5 97 235 06 3 94 154 99 1 90 74 78 310 6 72 264 47 4 21 165 65 2 44 95 99 2 15 84 69 1 57 61 62 6 17 242 74 4 06 159 99 1 96 77 09 320 6 93 273 02 4 34 171 01 2 51 98 97 2 23 87 67 1 64 64 60 6 36 250 41 4 19 164 99 2 02 79 41 330 7 15 281 57 4 48 176 36 2 59 101 94 2 30 90 65 1 72 67 57 6 56 258 08 4 32 169 98 2 08 81 72 340 7 37 290 12 4 62 181 72 2 67 104 92 2 38 93 62 1...

Page 11: ...and Africa Vivitek Service Support Zandsteen 15 2132 MZ Hoofddorp The Netherlands Tel 31 20 655 0960 Email support vivitek eu URL www vivitek eu China Vivitek Service Center 201209 Room 1802 18 F Cimic Tower No 1090 Century Avenue Pudong Shanghai Tel 400 888 3526 Toll Free Tel 021 58360088 142 Direct Email service vivitek com cn URL www vivitek com cn Asia and Taiwan VIVITEK after sales service Vi...

Reviews: