The Vivint Door and Window Sensor (DW12) is a security device that is installed
on doors, windows, and other objects in order to monitor and report open and
closed states. The DW12 transmits a signal to the control panel/hub when the
magnet is moved away from, or close to, the DW12 sensor.
The DW12 has an external input option for NC (Normally Closed) dry contact
connections, or it can be used with the provided magnet directly with the sensor.
The DW12 is also equipped with a cover tamper switch for additional security.
Installation Instructions
For internal switch usage (magnet):
1. Secure the sensor to the door frame using the adhesive or screws.
NOTE:
It is recommended to install the sensor on the side that will
be moving less (e.g. the frame instead of the door or window).
2. Secure the magnet adjacent to the sensor on the door or window
using the adhesive.
IMPORTANT:
The maximum allowable distance
between the magnet and the sensor is 0.7 in (17 mm).
NOTE:
If necessary, use the provided spacer to raise the magnet so
that it aligns better with the sensor. Remove the magnet's back
using a small flathead screwdriver and replace it with the spacer.
Installer / User Test
Open and/or close the door or window where the DW12 is installed to ensure the sensor is transmitting
correctly to the control panel/hub. The state change (open/closed) of the door or window should be recognized.
Door and Window Sensor
(VS-DW12-345)
PRINT INSTRUCTIONS:
REFERENCE SHEET FOR VS-DW12-345, P/N 77-600047-001 REV 1.0 |
INK:
BLACK |
MATERIAL:
20 LB MEAD BOND |
SIZE:
5.50" X 8.50" SCALE 1:1 |
FOLDS:
TRI-FOLD VERTICAL, TRI-FOLD HORIZONTAL (TO FIT IN BOX)
For external switch usage (NC dry contact):
1. Secure the external contact switch in the desired location.
2. If necessary, drill a hole to allow the wires to reach the sensor.
3. Feed the wires through the drilled hole and then the access hole.
4. Connect the wires into the NC dry contact connector.
NOTE:
With solid-core wire you should be able to push the wire
directly into the connector. Press the button to release the wire.
5. Mount the sensor in the desired location and reattach the cover.
NOTE:
Store any excess wire in the sensor.
Technical / Hardware Specifications
Vivint Part Number (P/N)
VS-DW12-345
Model Number (M/N)
DW02
Wireless Signal Range
350 ft. (106.7 m), open air
Battery
Panasonic CR2032 or
equivalent lithium battery
Battery Life
3-5 years (normal usage)
Transmitter Frequency
345 MHz
Code Outputs
Open, Close, Tamper, Low
Batt., Loss of Supervision
Supervisory Interval
70 minutes per signal (12
hours for panel/hub to
report supervision failure)
Operating Temp. Limits
32° to 120°F (0° to 49°C)
Relative Humidity
5-95% Non-Condensing
Standards Certifications & Listings
UL 634
Standard for Connectors and Switches
for Use with Burglar-Alarm Systems
ULC Subject
C634
Standard for Connectors and Switches
for Use with Burglar-Alarm Systems
FCC ID:
2AAAS-DW02
IC:
10941A-DW02