The Vivint Door and Window Sensor (DW12) is a security device that is installed 
on doors, windows, and other objects in order to monitor and report open and 
closed states. The DW12 transmits a signal to the control panel/hub when the 
magnet is moved away from, or close to, the DW12 sensor. 
The DW12 has an external input option for NC (Normally Closed) dry contact 
connections, or it can be used with the provided magnet directly with the sensor. 
The DW12 is also equipped with a cover tamper switch for additional security. 

Installation Instructions 

For internal switch usage (magnet): 

1. Secure the sensor to the door frame using the adhesive or screws. 

NOTE:

 It is recommended to install the sensor on the side that will 

be moving less (e.g. the frame instead of the door or window). 

2. Secure the magnet adjacent to the sensor on the door or window 

using the adhesive. 

IMPORTANT:

 The maximum allowable distance 

between the magnet and the sensor is 0.7 in (17 mm). 

NOTE:

 If necessary, use the provided spacer to raise the magnet so 

that it aligns better with the sensor. Remove the magnet's back 
using a small flathead screwdriver and replace it with the spacer. 

Installer / User Test 

Open and/or close the door or window where the DW12 is installed to ensure the sensor is transmitting 
correctly to the control panel/hub. The state change (open/closed) of the door or window should be recognized. 
 

Door and Window Sensor 

(VS-DW12-345)

 

 

PRINT INSTRUCTIONS:

 

 

 

 

REFERENCE SHEET FOR VS-DW12-345, P/N 77-600047-001 REV 1.0  |   

INK:

 BLACK  |  

MATERIAL:

 20 LB MEAD BOND  |  

SIZE:

 5.50" X 8.50" SCALE 1:1  | 

FOLDS:

 TRI-FOLD VERTICAL, TRI-FOLD HORIZONTAL (TO FIT IN BOX) 

For external switch usage (NC dry contact): 

1. Secure the external contact switch in the desired location.
2. If necessary, drill a hole to allow the wires to reach the sensor.

3. Feed the wires through the drilled hole and then the access hole.

4. Connect the wires into the NC dry contact connector. 

NOTE:

 With solid-core wire you should be able to push the wire

directly into the connector. Press the button to release the wire.

5. Mount the sensor in the desired location and reattach the cover.

NOTE:

 Store any excess wire in the sensor.

 

Technical / Hardware Specifications 

Vivint Part Number (P/N) 

VS-DW12-345 

Model Number (M/N) 

DW02 

Wireless Signal Range

 

350 ft. (106.7 m), open air 

Battery

 

Panasonic CR2032 or 

equivalent lithium battery 

Battery Life 

3-5 years (normal usage) 

Transmitter Frequency

 

345 MHz 

Code Outputs

 

Open, Close, Tamper, Low 

Batt., Loss of Supervision 

Supervisory Interval

 

70 minutes per signal (12 

hours for panel/hub to 

report supervision failure) 

Operating Temp. Limits

  32° to 120°F (0° to 49°C) 

Relative Humidity

 

5-95% Non-Condensing 

Standards Certifications & Listings 

UL 634 

Standard for Connectors and Switches 

for Use with Burglar-Alarm Systems 

ULC Subject 

C634

 

Standard for Connectors and Switches 

for Use with Burglar-Alarm Systems 

FCC ID: 

2AAAS-DW02 

IC: 

10941A-DW02 

*For complete regulatory compliance
information, go to

vivint.com/fcc