Main parts
Installation
Package included
1
2
3
4
Position of the Product:
When installation of the
product is completed, there
should be a clearance of
60cm between the product
and electric ranges and 65
cm between the product
and ranges using gas or
other fuels. (Figure 3)
1. Hood
2. Interior flue
connection bracket
with screws
3. User manual and
Installation,
Product fiche
4. Assembly Template
1. Height-adjustable
interior flue
2. Fixed exte rior flue
3. Cabinet
4. Control panel
5. LED Lighting
6. Alu Filter
ELECTRIC COOK
ER
G
A
S
COO
KER
(Figure 3)
WARNING!
Hood
should
not
be
connected to air channel
where there are other
smokes.