1.Temperature parameters
Indoor ambient temperature (Tinner ambient)
Indoor setting temperature (Tset)
2.System first power on
2.1 Cooling mode
2.1.2 Unit will stop for cooling
(1) Compressor will stop running
2.1.4 4-way valve control
Under this mode, 4-way valve will close (that is not electrified).
2.1.3 Switching from cooling mode to heating mode
Anti-freezing protection
Dehumidify mode
Heating mode
Unit will stop for heating
Working condition and procedure of cooling running
Cooling oil return condition
Outdoor unit fan motor control under cooling mode
Working condition and procedure of heating running
(2) Part of indoor unit arrive at unit stop running condition (Compressor will not stop)
When any one of indoor unit Tindoor amb Tpreset 2.5 , will start heating mode (turns on the heating and arrive at the unit on temperature)
Working condition and procedure of dehumidifying: the same with Cool mode; Protection function: the same with Cool mode. Close up 4-way
valve. The single unit capacity requirement percent of dehumidifying mode max. value is the cooling mode 90%, outdoor fan motor, compressor
start up condition is the same with that in Cool mode.
All indoor units arrived at unit off or unit stop condition: compressor will stop, outdoor fan unit will delay 1min will stop, all the elctrictron expansion
valve will start to work, when all valves turn to OP adjustment, the side valve will electrified, when turn the valve to 480P, the side valve will not
electrified.
After electrified, the side valve will be powered on, each electron expansion valve will be turned off orderly, then side valve will be powered off,
all the electron expansion valve should be turned to a certain angle, the unit on is standby.
Under each modes, once the compressor starts up, at least running for 7mins the unit will stop (not including
malfunction protection, modes switch the compressor needed to stop running);
Once compressor stopped, the unit will start up after 3mins delay (Heating oil return or defrosting except).
When cooling oil return, after compressor frequency rise up to 70Hz, it will stayabily run; Outdoor fan motor will accord to indoor unit will run at current
fan speed and after 1min delay to stop.
rating capacity total capacity and temperature automatically adjust the fan speed.
The oil return lasting time of cooling will be 5min. (including frequency rising time), oil return will be completed.
Compressor will stop running right away, outdoor fan motor will delay 1min and will stop running, all the electron expansion valve starts to work, when
turns off all valves at OP, the side valve will be electrified, the valve fully turns to 480P, the side valve will turn off.
When turning to heating mode, after compressor stopped, 4-way valve will electrify after 2mins delay, the others are the same with cooling.
If compressor stopped and turn on the unit for cooling, if any one indoor unit (Tindoor amb. Tpreset) 0.5 , that the cooling will run;
at this time, the outdoor fan motor, compressor starts to run, the compressor frequency will run at the capacity requirement calculated.
When it is satisfied with anti-freezing protection, the system will enter into anti-freezing protection, at this time only some of the indoor unit anti-freezing
protection, indoor capacity will be set as 0; when all running indoor unit act the anti-freezing protection, the unit will process as Cool mode. When it is
satisfied with the anti-freezing protection finished, the anti-freezing protection will be finished.
Compressor will run according to capacity requirement calculated frequency, when capacity requirement is 0 indoor unit corresponding electron
expansion valve 5s turns off, compressor frequency variable start meanwhile running indoor unit (no matter it is newly opened or indoor unit
has been run) the corresponding electron expansion valve resumes to the original value.
NOTE: Unit off, Fan, Protection as the same with Cool mode;
Before compressor start 5s start cooling, after outdoor fan motor start up and run in high speed for 3min, then according to the indoor unit rated capacity
total amount and outdoor ambient temperature, automatically select High, Mid, Low three fan speeds.
Other control: When the newly opened indoor unit is running, outdoor fan motor will run at high fan speed for 40s, then according to control logic to
adjust. Fan motor each grade at least run 80s (when indoor unit running quantities change and calculate indoor unit rated capacity total amount
and according to temperature to adjust the fan speed.) When compressor stops running, outdoor fan will run at
Summary of Contents for ACP-24COFM70GEI
Page 1: ...ACP 24COFM70GEI ACP 28COFM80GEI RoHS Service manual ENG ...
Page 2: ......
Page 5: ...Wrench Bolt Nut Unit mm Model ACP 24COFM70GEI ...
Page 6: ...Wrench Bolt Nut Unit mm Model ACP 28COFM80GEI ...
Page 11: ...Model ACP 24COFM70GEI ...
Page 12: ...Model ACP 28COFM80GEI ...
Page 23: ...2 ACP 28COFM80GEI ...
Page 35: ......
Page 36: ......
Page 37: ......