4GOQXCN2TQEGFWTG
Remove the screws connecting mid-isolation board,
chassis and condenser assy, to remove the
mid-isolation.
12. Remove mid-isolation board
mid-isolation board
Welding cut the spot weld of four-way valve assy,
compressor air suction/discharging valve and
condenser pipe outlet, lift to remove the four-way valve
assy. (Note: release the refrigerant before welding
cutting.)
13. Remove four-way valve assy
four-way valve assy
Remove the three feet screw nuts fixing compressor,
to remove the compressor.
14. Remove compressor
compressor