Operating Procedures / Photos
Disassemble Motor and Motor Support
Unscrew the four tapping screws fixing the motor,
and remove the motor. Unscrew the two tapping
screws fixing the motor support, and lift the motor
support to remove it.
Motor Support
tapping screws
Motor
(refer to Figure
7
-
2
0)
Figure
7
-
2
0
Disassemble 4-Way Valve
Screw off the holding nut of the 4-way valve coil
and remove the coil. Use wet cotton cloth to wrap
the 4-way valve, unsold the four soldering points
connecting the 4-way valve, and remove the
4-way valve. Be quick during the unsoldering
process, pay attention to keep the wrapping cloth
wet and do not allow the soldering flame to burn
the compressor lead-out cable.
4-way valve
soldering points
holding nut
(Note: only after discharging all freon).
(refer to Figure
7
-
21
)
Figure
7
-
21
Disassemble Capillary Subassembly
Unsolder the soldering points connecting the
capillary
subassembly
and the other pipelines, and
remove the capillary
subassembly
.
Capillary Subassembly
Figure
7
-
22
(refer to Figure
7
-
22
)
Summary of Contents for ACP-09CH25GEI
Page 1: ...ACP 09CH25GEI ACP 12CH35GEI RoHS Service manual ENG ...
Page 2: ......
Page 15: ...5 5 5 5 5 Electrical Diagram ...
Page 16: ......
Page 17: ...ACP 09CH25GEI ...
Page 18: ... L 0 0 0 L 0 0 0 ACP 12CH35GEI ...
Page 42: ...Exploded View of Components and Parts of Indoor Unit ...
Page 44: ...Exploded View of Components and Parts of Indoor Unit ...
Page 46: ...Exploded View of Components and Parts of Indoor Unit ...
Page 48: ...Exploded View of Components and Parts of Outdoor Unit ...
Page 50: ...Exploded View of Components and Parts of Outdoor Unit ...
Page 52: ...Exploded View of Components and Parts of Outdoor Unit ...
Page 54: ...Exploded View of Components and Parts of Outdoor Unit ...
Page 56: ...Exploded View of Components and Parts of Outdoor Unit ...
Page 58: ...Exploded View of Components and Parts of Outdoor Unit ...
Page 68: ......
Page 69: ......
Page 70: ......