26
cooling mode, defrosting mode and the current protection.
7.4.2.3 Indoor fan running rules
In cooling mode, indoor fan runs all the time and the speed can be selected as high, medium, low and
auto.
The auto fan:
T1-Ts
High
Low
Medium
7.4.2.4 Evaporator low temperature T2 protection.
T2
On
Off
When the evaporator coil temp.T2 keeps lower than setting value, the compressor and outdoor fan will
shut off.
7.4.3 Heating Mode (For Heating & Cooling models)
7.4.3.1 Compressor running rules:
When indoor room temp.T1 is higher than setting value the compressor and outdoor fan will shut off.
Summary of Contents for ACP-09CH25AERO