1.5 - M
ECHANICAL
INSTALLATION
Unpacking / Installing mySelective.com
C
HAPTER
1
7
1.5
M
ECHANICAL
INSTALLATION
After carefully positioning the machine and allowing for sufficient working space we can continue
installation.
The procedures given here are meant as a directive for measuring and controlling the machine, in
order to guarantee that the machine will run as specified.
During some measurements the robot must be set over the camera position. In that case it is
usefull that the robot will function electrically and mechanically in accordance with the specifica-
tions and with the correct software.
For operating the robot, which is necessary to set the robot over the camera position, see User
manual.
1.5.1 M
EASURING
CONDITIONS
Before measuring the machine has to come at environmental temperature.
If the measurements have to be done otherwise than with solderpots and preheating in a
'switched off' position, it will be notified in the procedure.
1.5.2 M
EASURING
METHODS
Unless otherwise specified we will make use of standard available measuring tools.
1.5.3 M
EASURING
TOOLS
•
Machine spirit level 0.1 mm/m scale division.
•
Square frame spirit level 0.1 mm/m scale division.