– 6 –
• Periodic maintenance of the bridge saw will
prevent unnecessary problems. Keep the
ventilation slots of the bridge saw clean to
prevent overheating of the motor.
• Dry the bridge saw as much as possible
after using.
Pump Maintenance
Warning! — Always disconnect from electrical
outlet before handling the pump.
• Do not let the pump run dry.
• Do not lift the pump by the power cord.
• Do not pump heated liquids.
• Operate in freshwater only.
• Operate pump completely submerged for
proper cooling.
intake
cover
flow
regulator
impeller
cover
impeller
motor head
outlet
FIGURE 16
A clogged or dirty intake cover will greatly
reduce performance. If the pump is used in
dirty water, raise it slightly to reduce the amount
of debris contacting the intake. If
less flow is desired, adjust the flow regulator
on the front of the pump.
Do not let the pump run when not submerged in
water. Doing so may damage the pump. Always
submerge the pump first, and then plug in the
electrical outlet. If the pump does not function
straight away, switching the power on and off
several times will normally correct this.
To clean the pump, remove the intake cover
and the impeller. Use a small brush or stream of
water to remove any debris.
TROUBLE SHOOTING
If The Pump Fails To Operate,
Check The Following:
• Che
ck the circuit breaker and try another power
source to ensure the pump is getting electrical
power.
NOTE:
Always disconnect from
electrical outlet before handling the pump.
•
Check the pump discharge and tubing for kinks
and obstructions. Algae build up can be flushed
out with a jet of water.
•
Check the intake cover to ensure it is not
clogged with debris.
•
Remove the intake cover to access the
impeller area. Turn the impeller to ensure it is
not broken or jammed.
•
Monthly maintenance will add to your
pump’s life.
NOTE:
Ensure that the electrical cord loops
below the electrical outlet to form a “Drip
Loop.” This will prevent water from running
down the cord into the electrical outlet.
Replacing The Pump
If the pump still does not work, you have to
replace pump with a new one. Only use the pump
recommended by the manufacturer of the bridge
saw. Call the Technical Helpline on 01253 789180
or return to location of purchase.
The changing procedures are as follows:
1. Loosen the bolt of the pump connecting box
located on one end of main frame and remove
the cover.
2. Loosen the bolt of the pump cable lock and
take the pump plug out of connecting box (see
FIGURE 17).
FIGURE 16
3. Take out the pump and replace a new one,
install the new pump by reversing the above
procedures.
ACCESSORIES
• 45-degree angle guide
• Parallel rip fence
• Hexagonal blade wrench
• Motor shaft holding wrench
08