Assembly Screw
(4x14mm)
Torque Wrench
Assembly Screw
(4x12mm)
Mounting Screw
(4x30mm)
1. Locate the mounting template at the installation position and drill the ceiling
or wall if needed.
2. Open the dome cover by loosening screws(4x12mm). Use the torque wrench
supplied.
4. Set the cameras viewing angle.
- Route the Power cable to the connecting place.
.
A
Flush mount type
A. Flush mount type:
B. Surface mount type (Option):
B
Surface mount type
3
5. Replace the dome cover to the dome base unit and tighten the assembly screws.
- Place the surface mount on pre-drilled position and attach using mounting
screws (4x30mm). Assemble the cable conduit, otherwise tighten a conduit hole
cap.
- Route the Power cable to the connecting place.
- Affix the dome base unit to the surface mount using the assembly screws
(4x14mm). Before attaching the dome base make sure the assembly holes are
aligned with the surface mount assembly holes.
See Optional Dome Mounts (pg. 3)
Flush Mount Installation
requires a Flush Mount
Decorator Plate
(See pg. 3)
See Optional Dome Mounts (pg. 3)
.
Installation Instructions
CAUTION
15
…
90
…
Limit of pan & tilt
1) Pan limit:
Pan is limited to +/- 165°. Do NOT force the gimbal over the limit, this will
prevent internal damage.
2) Tilt limit:
Tilt is limited to 15° min ~ 90° max. with reference to the ceiling when the
inclination of camera module is 0°, that is, the image is aligned horizontally.
3) Inclination limit (Horizontal image alignment):
Inclination limited to +/-60° max.
• Extreme care should be taken NOT to scratch the bubble dome surface while
installing or adjusting the camera.
• Care should be taken that the cable is NOT damaged, kinked or exposed in
a hazardous area.
• Tighten the dome cover mounting screws so that there is NO gap between Lens
hood and clear bubble to avoid IR reflection
.
0.2M
VIDEO (BNC)
AC24V/GND (Black wire)
AC24V/DC12V (Red wire)
RTX- (Gray wire)
RTX+ (White wire)
Power Supply Connections
Make sure the power is removed before installation.
Camera can work with either 24VAC or 12VDC, dual voltage power.
Primary and secondary grounds are completely isolated to avoid the possible
ground-loop problems.
In case that HD-SDI Inputs are not supported by Monitor, please use HD-S DI
Converter to connect HD-SDI cable with Monitor
Some computer monitors or TVs may not support 30p/25p.
Please check Specification of Monitor before installation.
LIMITED LIABILITY WARRANTY
VITEK products carry a three (3) year limited warranty. VITEK
warrants to the purchaser that products manufactured by VITEK
are free of any rightful claim of infringement or the like, and when
used in the manner intended, will be free of defects in materials and
workmanship for a period of three (3) years, or as otherwise stated
above, from the date of purchase by the end user. This warranty is
nontransferable and extends only to the original buyer or end user
customer of a VITEK Authorized Reseller.
The product must have been used only for its intended purpose, and
not been subjected to damage by misuse, willful or accidental damage,
caused by excessive voltage or lightning.
The product must not have been tampered with in any way or the
guarantee will be considered null and void.
This guarantee does not affect your statutory rights.
Contact your local VITEK Reseller should servicing become
necessary.
VITEK makes no warranty or guarantee whatsoever with respect to
products sold or purchased through unauthorized sales channels.
Warranty support is available only if product is purchased through a
VITEK Authorized Reseller.
Version 1.1
Sept 2014
28492 CONSTELLATION ROAD
VALENCIA, CA 91355
WWW.VITEKCCTV.COM
Installation Instructions
Installation Instructions
Flush Mount
Decorator Plate
- Place the dome base unit on pre-drilled position and attach using mounting
screws (4x30mm).
5
7
8
6