Press “ESC” to cancel the settings. 

 

To create Track 

1. Select a TV wall. For example, enter “1” and press “MON”. 

2. Select a window. For example., enter “3” and press “WIN”. 

3. Enter the track number on the keyboard and then press and hold “ TRACK” for more than 

two seconds. 

4. Move the joystick to control the moving track of the PTZ and then press “ENTER” to save 

the settings. Press “ESC” to cancel the settings. 

 

To call cruise/track 

1. Select a TV wall. For example, enter “1” and press “MON”. 

2. Select a window. For example, enter “3” and press “WIN”. 

3. Select a cruise/track. For example, enter “1” and press “CRUISE/TRACK”. 

 

   

 

 

To stop cruise/track 

1. Select a TV wall. For example, enter “1” and press “MON”. 

2. Select a window. For example, enter “3” and press “WIN”. 

3. Select a cruise/track. For example, enter “0” and press “CRUISE/TRACK”. 

 

   

 

 

5.6.4 Focus +/- 

To set focus +/- 

1. Select a TV wall. For example, enter “1” and press “MON”. 

2. Select a window. For example, enter “3” and press “WIN”. 

3. Press “FOCUS+” or “FOCUS-”. 

 

Summary of Contents for VT-TKBD11

Page 1: ...figuration by Web Client Supports PTZ Mode and Platform Mode Controls up to 256 PTZ Cameras in PTZ Mode Playback Control of TV Wall Client Macro Setup and Calling Linked Display Window Picture in Picture Roaming Control Multi Language Support English Spanish Chinese Polish 3 Year Warranty PLEASE NOTE Complete User Guide Software Tools and Updates are available online Scan the QR Code or visit http...

Page 2: ...ed The content is subject to change without notice NOTE The LCD display can be easily damaged Do not press the display or expose it to sunlight for prolonged periods The joystick can also be easily damaged If it requires repair please wrap it and ship it using the original or safety packaging Items Qnty Note Network keyboard 1 DC12V power adapter 1 Input AC100 240V Power cable 1 ...

Page 3: ...Setup 7 2 2 5 Question Setup 7 2 2 6 Playback Set 7 2 3 PTZ Setup 7 2 4 Mode Setup 8 2 5 Language Setup 8 2 6 Test 8 3 PTZ Mode 9 3 1 Mode Setup 9 3 2 PTZ IP Setup 9 3 3 PTZ Operation 9 3 4 PTZ Shift 10 4 Serial Port Mode 11 4 1 Mode Settings 11 4 2 Setting PTZ parameters 11 4 3 PTZ Control 11 5 Decoding 12 5 1 Call Layout 12 5 2 Screen Display Mode 13 5 3 Camera Monitor 14 5 4 Camera Group Window...

Page 4: ...able Light 19 5 6 9 Enable Disable Wiper 19 5 7 Record Playback 19 5 7 1 Start Playback 19 5 7 2 Pause Playback 19 5 7 3 Play the Previous 30s 19 5 7 4 Play the Next 30s or Frame 20 5 7 5 Stop Playback 20 6 Others 21 6 1 View Information 21 6 2 Lock 21 7 Web 22 7 1 Web Access 22 7 2 Upgrade 23 8 Detailed Specifications 24 Appendix 25 ...

Page 5: ...DIMENSIONS NOTES ...

Page 6: ...screen of the keyboard so that it is easy to use 1 2 Rear Panel Instructions Name Description PW When the network keyboard is working the power indicator turns red LINK The network status indicator RS232 Internal testing port RJ45 RJ45 network port RS485 Connect speed dome TA connects to RS485 TB connects to RS485 DC 12V DC12V power input WIFI Unavailable Grounding 1 3 Front Panel Instructions ...

Page 7: ...dow of the current output CAM Select the camera MULT Set the screen display mode of the current output MON G Select the output group monitor group unavailable CAM G Select the input group camera group LAYOUT Call scheme AUDIO Enable disable audio of the selected window unavailable Play Pause Stop Enable disable manual record unavailable Jump to the previous 30 seconds from the current playing time...

Page 8: ...le the auto scan FOCUS Click to focus out FOCUS Click to focus in ZOOM Zoom in ZOOM Zoom out IRIS Iris increases IRIS Iris decreases WIPER Enable or disable wiper LIGHT Enable or disable light 1 4 Rules of Pressing Keys Press twice This is used to switch the alphabet The interval time between two presses should be less than 2 seconds For example press 2 twice to input A press 2 three times to inpu...

Page 9: ...t Right PTZ control mode control the speed dome to move right Upper left PTZ control mode control the speed dome to move towards upper left Upper right PTZ control mode control the speed dome to move towards upper right Lower left PTZ control mode control the speed dome to move towards lower left Lower right PTZ control mode control the speed dome to move towards lower right Rotate left Zoom in Ro...

Page 10: ...assword setup menu and press Enter key to go to the password setup Enter the old password by moving the joystick right one by one the default password is 123456 Select the new password by moving the joystick down and then enter the new password as the mentioned above Finally confirm the new password and press Enter key to save the settings If you want to change the inputted number please move the ...

Page 11: ...P address and PTZ IP address must be in the same local network segment Ø Local IP Setup To change the IP scheme of the keyboard select Local IP Setup and press Enter to go to local IP setup You can set the local IP address subnet mask default gateway DNS server alternate DNS and HTTP port v IP address Select IP address and press Enter to set the IP address The default IP address is 192 168 1 201 T...

Page 12: ...cendent VMS v Port The default port is 56789 The port must be the same with that of the TV Wall Client v Name and password The name and password must be the same with that of the TV Wall Client v Test To test if the keyboard is online Ø PTZ IP Setup Please see 3 2 PTZ IP Setup for details 2 2 4 Default Setup Select and press Enter to restore the system to factory default settings 2 2 5 Question Se...

Page 13: ...de PTZ mode and serial port mode 2 5 Language Setup Select and press Enter to switch the language between English Chinese Polish Spanish Hungarian and Italian 2 6 Test Select and press Enter to test if the button is available The user can also check if the silk screen on the button and display on the screen is consistent ...

Page 14: ...up Go to Network Setup to select PTZ IP Setup and press Enter Then set the IP address port name password of the PTZ selected v IP address Enter the IP address of the PTZ This IP address must be in the same local network segment with the local IP address of the network keyboard v Port The default port is 80 the http port of the PTZ v Name and password The name and password must be the same with tha...

Page 15: ...support shifting the PTZs by pressing Number plus SHIFT Select another PTZ and setup the IP address port name and password Please see 3 2 PTZ IP Setup for more details Press SHIFT to switch the PTZs of which the IP address is setup ...

Page 16: ... Please select it according to the protocol of the PTZ camera Address The effective value is from 1 to 255 Please set it according to the address of the PTZ camera Baud rate 1200 2400 4800 9600 or 19200 can be set Please set it according to the baud rate of the PTZ camera 4 3 PTZ Control After the above parameters are set please return to the main operation interface The PTZ camera can be controll...

Page 17: ...and then press MON key to select No 1 TV wall 2 Select a plan layout For example enter 1 and then press LAYOUT key to select Layout 1 To set a Plan Go to the TV wall view interface and then select the plan tag to add a plan Double click the plan name to show the plan Then drag the monitoring points to the corresponding window respectively to decode images After that click Save or Save As to save t...

Page 18: ... 3 window of TV wall 1 will be switched to 25 screen display mode Note The effective value is from 1 to 999 The maximum number of the screen display mode of platform surveillance is 36 screens As a result the maximum of 36 screens can be called when controlling the TV wall Operation Go to TV Wall ManagementàTV Wall Setting interface to create a TV wall Then double click the TV wall name to view th...

Page 19: ...endent VMS go to TV Wall ManagementàTV wall System Setting Note The effective value of the camera is 1 to 999999 When entering 0 and pressing CAM it means to stop playing the current image 5 4 Camera Group Window Select the camera group to the designated window The camera group will be played in sequence in this window The setting steps are as follow 1 Select a TV wall For example enter 1 and then...

Page 20: ...instructions are saved in the keyboard The setting steps of macro are as follow 1 Enter the digital number and then press and hold MACRO key to set macro For example enter 2 and press MACRO key for more than 2 seconds to set NO 2 macro 2 Enter a series of keys For example enter 1 and press MON enter 2 and press WIN enter 2 and press CAM 3 Press Enter to complete the macro setup Input digital numbe...

Page 21: ...r 1 and then press MON 2 Select a window For example enter 3 and then press WIN 3 Set the position of the preset by moving joystick 4 Press the digital number on the keyboard to select the number of preset Then press PRESET for more than 2 seconds to set the preset For example enter 1 and then press PRESET for more than 2 seconds to set the NO 1 preset To call preset 1 Select a TV wall For example...

Page 22: ...SC to cancel the settings To call cruise track 1 Select a TV wall For example enter 1 and press MON 2 Select a window For example enter 3 and press WIN 3 Select a cruise track For example enter 1 and press CRUISE TRACK To stop cruise track 1 Select a TV wall For example enter 1 and press MON 2 Select a window For example enter 3 and press WIN 3 Select a cruise track For example enter 0 and press C...

Page 23: ...o set iris 1 Select a TV wall For example enter 1 and press MON 2 Select a window For example enter 3 and press WIN 3 Press IRIS or IRIS 5 6 7 Start or Stop Auto Scan To start or stop auto scan 1 Select a TV wall For example enter 1 and press MON 2 Select a window For example enter 3 and press WIN 3 Press AUTO to start auto scan press AUTO again to stop auto scan ...

Page 24: ...t 5 7 Record Playback 5 7 1 Start Playback You can playback the recording saved in the storage server of the Transcendent VMS To play the record 1 Select a TV wall For example enter 1 and press MON 2 Select a window For example enter 3 and press WIN 3 Press key to play the recording 5 7 2 Pause Playback When the recording is in playing mode in the current window press the pause key to pause playba...

Page 25: ... you may play the next frame The setting steps are as follow 1 Select a TV wall For example enter 1 and press MON 2 Select a window For example enter 3 and press WIN 3 When the recording is playing press key to play the recording of the next 30 seconds When the recording is paused press key to play the next frame 5 7 5 Stop Playback When the recording is playing or paused you may stop playback The...

Page 26: ...he joystick down 6 2 Lock You can lock the keyboard by pressing LOCK key Enter the password the default password is 123456 to unlock the keyboard When the keyboard is locked all keys except digital keys on the keyboard are unavailable until you input the password to unlock the keyboard Tips After inputting wrong password more than 3 times you can reset password by answering the security questions ...

Page 27: ...default password is 123456 v Please make sure the IP address of the web client is in the same local network as that of the keyboard If the IP address of the keyboard is 192 168 001 201 the IP address of the IP client must be 192 168 001 XXX v Some models may be searched by IP Tool Make sure the PC and keyboard are connected to the LAN and double click the IP Tool icon to run this software Then the...

Page 28: ...Click Browse button to select the save path of the upgrade file 2 Click Upgrade server firmware to start upgrading the application program 4 After successfully update the software the device will restart automatically Notice You cannot disconnect to PC or close the keyboard during upgrade ...

Page 29: ...ol Mode PTZ Mode and Platform Mode Network Management Network Keyboard can be Configured and Software can be Upgraded by Web Client Serial Port Two standard serial ports RS485 1 RS232 1 Bit Rate 1200bps 2400bps 4800bps 9600bps 19200bps Power Supply DC12V Power Consumption 8W Working Temperature 14 140 F 10 60 C Working Humidity 10 90 Dimension L W H 14 17 7 81 4 10 360 198 104mm Weight Net Gross 4...

Page 30: ... Reseller The product must have been used only for its intended purpose and not been subjected to damage by misuse willful or accidental damage caused by excessive voltage or lightning The product must not have been tampered with in any way or the guarantee will be considered null and void This guarantee does not affect your statutory rights Contact your local VITEK Reseller should servicing becom...