C O P Y O F O R I G I N A L M A N U A L – O S E - C 1 0 0 1
Release: 2012-06-04
VITECTOR GmbH
5 / 6
Carlswerkstr. 13c, D - 51063 Köln
Tel.: +49 (0) 221 - 9 62 13-0, T49 (0) 221 - 9 62 13-60, www.vitector.de, [email protected]
GB
Hi
Te
st
Te
st
Low
GND
GND
+24V
+24V
Test Signal
Terminal assignment
Terminal designation
Function
+ - 24 V AC/DC
Power supply (when supplied with DC note po and -)
Test
Input for test signal
NC
Safety-related output, is opened when safety edge is activated
COM
Common contact for NO and NC output
NO
Non safety-related contact, is closed when safety edge is activated
bn
12 V – supply voltage of the OSE Transmitter and Receiver (brown cable)
wh
0 V – supply voltage of the OSE Transmitter and Receiver (white cable)
gn
Signal Input for Transmitter and Receiver (green cable)
Wiring Diagram
GN
www.vitector.com
OSE
Te
s
t
BN
WH
24V
N
O
N
C
OSE-C 1001-V3.0
C
o
m
AC/DC
Hi
Low
Te
st
- 24V +
TEST
< 0,5 A
Indication LED
LED
Function display
OSE
Safety Edge is Ok
Operating status, fault diagnosis, trouble-shooting
Indication
Operating status
Possible cause
Remedy
LED “OSE” lights
All is right
LED “OSE” is not lit
Not ready
Supply voltage defective or
polarity is wrong
Check supply voltage
No Test input connected or
Jumper “test” connected wrong
Connect Test input with test signal of control unit,
possibly switch jumper
Safety edge OSE defective
Check wiring of OSE safety edge
Jumper „Test“
Contact
Function
Hi
Test is High Activ
Low
Test is Low Activ