background image

 

 

C O P Y   O F   O R I G I N A L   M A N U A L   –   O S E - C   1 0 0 1  

Release: 2012-06-04 

VITECTOR GmbH 

5 / 6 

Carlswerkstr. 13c, D - 51063 Köln 

Tel.: +49 (0) 221 - 9 62 13-0, T49 (0) 221 - 9 62 13-60, www.vitector.de, [email protected] 

GB 

Hi

Te

st

Te

st

Low

GND

GND

+24V

+24V

Test Signal

Terminal assignment 

Terminal designation 

Function 

+ - 24 V AC/DC 

Power supply (when supplied with DC note po and -) 

Test 

Input for test signal 

NC 

Safety-related output, is opened when safety edge is activated 

COM 

Common contact for NO and NC output 

NO 

Non safety-related contact, is closed when safety edge is activated 

bn 

12 V – supply voltage of the OSE Transmitter and Receiver (brown cable) 

wh 

0 V – supply voltage of the OSE Transmitter and Receiver (white cable) 

gn 

Signal Input for Transmitter and Receiver (green cable) 

 

Wiring Diagram 

GN

www.vitector.com

OSE

Te

s

t

BN

WH

24V

N

O

N

C

OSE-C 1001-V3.0

C

o

m

AC/DC

Hi
Low

Te

st

- 24V +

TEST

< 0,5 A

 

Indication LED 

LED 

Function display 

OSE 

Safety Edge is Ok 

 

Operating status, fault diagnosis, trouble-shooting

 

Indication 

Operating status 

Possible cause 

Remedy 

LED “OSE” lights 

All is right 

 

 

LED “OSE” is not lit 

Not ready 

Supply voltage defective or 

polarity is wrong 

Check supply voltage 

 

 

No Test input connected or 

Jumper “test” connected wrong 

Connect Test input with test signal of control unit, 

possibly switch jumper 

 

 

Safety edge OSE defective 

Check wiring of OSE safety edge 

 

Jumper „Test“ 

Contact 

Function 

Hi 

Test is High Activ 

Low 

Test is Low Activ 