VitBest
5
RS232 Protocol
& - Command, $ - Query, ^ Response
<cr> = 0x0D Hex / 13 Decimal
Command VitBest
String
Information Example Example
String
Example
Response
Route
Command
&Ra<cr
>
A=V or H;
V mean VGA,
H mean HDMI.
Route
VGA
Input to
HDBT
Output
&RV<cr> ^RV<cr>
OR No VGA
Signal Input
Query
Active
Rourte
$R<cr>
$R<cr>
^RV<cr>
Baud Rate
Setup
Command
&Bab<cr
>
a=baud
rate=9600,19
200,38400
b=bits,parity,
stop=8N1,8E1
,801
Set
RS232
Port Baud
Rate
to
96008N1
&B96008
N1<cr>
^B96008N1
<cr>
Query Baud
Rate
$B<cr>
Response
shows
38400
8N1
$B<cr>
^B384008N
1<cr>
Query
Firmware
$FM<cr
>
Query
Processor
firmware
$FM<cr> ^FM-1.0.0<
cr>
Note:
The default baud rate is 38400.