Measuring

After correctly positioning the cuff and selecting the user 
you are measuring for, press the “Start” button to activate and 
complete the measurement process.
Press the “Stop” button at anytime during the 
process to stop the measurement.
One completed, press the “Stop” button to 
turn off the monitor otherwise it will turn off 
automatically.

Taking a

 Measurement

Caution

 When using this device, please pay attention to the following situations which may interrupt blood flow 
and influence blood circulation, thus having the potential to cause injury to the patient:  too frequent 
or consecutive measurements; the application of the CUFF and its pressurization on any arm where 
intravascular access or therapy, or an arterio-venous (A-V) shunt, is present; Inflating the cuff on the arm on 
the side of a mastectomy.

Do not apply the cuff over a wound, doing so may cause further injury. Do not inflate the cuff on the same 
limb which other monitoring equipment is applied around simultaneously, this could cause temporary 
loss of function of those simultaneously-used monitoring equipment.  Don’t link the connection tube, to 
anything that can result in the cuff pressure continuously increasing  which can prevent blood flow and 
result in harmful injury.

12

Summary of Contents for ProSeries 2

Page 1: ...ProSeries 2 Blood Pressure Monitor Quick Start Guide A complete user guide is available at vitasigns com VS47129 0200 ...

Page 2: ... and fitness goals Our intelligent devices improve your health awareness by making it easy to measure monitor and track your weight pulse rate blood pressure steps activity and more Every day people just like you choose our products We honor that choice by ensuring our products are the highest quality and by doing business responsibly Thank you for making Vitasings part of your life ...

Page 3: ... Measurement Tips 11 Taking a Measurement 12 Records Management 13 Maintenance 14 Vitasigns Application 15 Systolic Diastolic Pressure 17 Standard Blood Pressure 18 Irregular Heartbeat Detector 19 Frequently Asked Questions 20 Troubleshooting 21 Specifications 22 Complied Standards 23 FCC Statement 24 EMC Guidance 24 Table of Contents ...

Page 4: ...rmined with this device are equivalent to those obtained by a trained observer using the American National Standard Manual Electronic or automated sphygmomanometers If you suffer from disorder of heart rhythm arrhythmia only use this blood pressure monitor after consulting with your physician In certain oscillometric cases this measurement method may produce incorrect readings This Vitasigns measu...

Page 5: ...y Class II Equipment Type BF Applied Parts Direct Current T1A 250V ø3 6 10CCC Manufacturer Date ENVIRONMENT PROTECTION Wast electrical products should not be disposed of with house hold waste Please recycle where facilities exist Check with your local authority or retailer for recycling advice Safety Information F1 2 ...

Page 6: ...ed for use on body extremities other than the wrist Its sole functions are blood pressure and heart rate measurement Monitoring blood pressure with this device does not equate to a medical diagnosis This device allows you to monitor your blood pressure under the care of a physician If you are taking medication consult with your physician to determine the most appropriate time for your measurement ...

Page 7: ...cal radio frequency equipment that radiates interference signal or electrical fast transient burst signal The device is not AP APG equipment It is not suitable for use in the presence of flammable gases avoid oxygen nitrous oxide Keep the unit out of reach of infants or children Inhalation or swallowing of the device s small pieces is dangerous or even fatal Use only accessories and detachable par...

Page 8: ...Norm Hype G3 G2 G1 Hypo Memory Review Start Stop Mem Set ProSeries2 LCD Display ...

Page 9: ...w Mode Systolic Blood Pressure Low Battery Indicator Heartbeat Detection Pulse Rate Per Minute Date and Time Indicator Irregular HeartbeatDetected Average of Last 3 Reading Showing UserIndicators User1 User2 AppearsNextto BloodPressureGrade Important Symbols 6 ...

Page 10: ... Avoid direct contact with fire and the heat sources as the can cause the battery to explode Only use theVitasigns authorized USB cable to charge your ProSeries2 The ProSeries 2 can not be used while charging When the charging indicator disappears from the display charging is complete and you may unplug and use the ProSeries 2 Charging Your Pro Series 2 The Pro Series 2 Blood Pressure Monitor cont...

Page 11: ...MEM SET Norm Hype G3 G2 G1 Hypo Mem Up Button Systolic Pressure USB Interface Diastolic Pressure Pulse Rate Date Time Set Down Button Start Stop Button ProSeries2 Components 8 ...

Page 12: ...3 Press the Mem button to change the number Each press will increase the number by 1 4 Press the Set button to confirm the change and move onto minutes 5 Repeat this same process for minutes month day and year 6 Once you have confirmed the year dONE will appear on the screen and the monitor will shut off automatically SelectingaUser 1 With the Pro Series 2 off press and hold in the Mem button for ...

Page 13: ...roll or push up your sleeve to expose your skin 3 Fasten the cuff around your wrist palm facing up and fasten 4 Make sure the cuff is firmly against your skin if the cuff is too loose the measurement will not be accurate 5 Sit comfortably on a chair The center of the cuff should remain at the same level as your heart Your legs should be relaxed with the feet facing outwards Preparing to Measure 10...

Page 14: ...owing these additional tips when taking a measurement to get a more accurate reading Measurement taking under any of the following circumstances may result in inaccurate readings Measuring Tips Don tmeasure immediately afterdrinkingtea coffee orsmoking Waitatleast1 hourtomeasure aftereatingor drinking Don tmeasure whiletalkingor movingyourhands andfingers Waitatleast20 minutestomea sureafterbathin...

Page 15: ...ving the potential to cause injury to the patient too frequent or consecutive measurements the application of the CUFF and its pressurization on any arm where intravascular access or therapy or an arterio venous A V shunt is present Inflating the cuff on the arm on the side of a mastectomy Do not apply the cuff over a wound doing so may cause further injury Do not inflate the cuff on the same limb...

Page 16: ...n the Pro Series 2 by entering the recall records mode and then holding in the both the Set and Mem buttons for 3 seconds The display will show dEL d0NE indicating that the memory has been cleared completely The monitor will shut down automatically when finished Remember the average value of the latest three readings is always shown first Records Management Caution The most recent record 1 is show...

Page 17: ...hile the device is in use If you have any problems with this device such as setting up maintaining or using please contactVitasigns info vitasigns com Do not open or repair the device by yourself Please report toVitasigns if any unexpected operation or events occur Cleaning Dusty environments may affect the performance of the unit Please use a soft cloth to remove any dirt from the device and cuff...

Page 18: ...and Pulse Rate as part of your Smart Routine for health awareness Enter your readings into the Vitasigns App to store data monitor progress set and achieve goals or even share your information with a personal trainer or physician Download the Vitasigns App for free from the Apple App Store or Google Play www vitasigns com app OPTIONAL FREE APP ...

Page 19: ...word 2 Enter your name and select your gender 3 Select your birthday 4 Enter your height and weight 5 Select or take a photo of yourself to be used as your account avatar 6 Confirm that your information is correct and press the OK button You can use the Vitasigns App to track your progress on the Pro Series 2 Blood Pressure Monitor by manually entering your results after each measurement Keeping a...

Page 20: ...blood pressure When ventricles contract and pump blood out of the heart the blood pressure reaches its maximum value in the cycle which is called systolic pressure When the ventricles relax the blood pressure reaches its minimum value in the cycle which is called diastolic pressure Systolic Diastolic Blood Pressure 17 ...

Page 21: ...rtension Stage 2 160 or higher or 100 or higher Hypertensive Crisis Emergency Care Needed Emergency Care Needed Higher than 180 or Higher than 110 SYS 135 mm Hg DIA 85 mm Hg The chart below shows the standard blood pressure classifications published by the American Heart Association AHA AHA Home Guideline for Upper Limits of Normal Blood Pressure are Please consult a physician if your measurement ...

Page 22: ...er than or equal to 15 the IHB symbol will display on the screen with the measurement result Irregular Heartbeat Detection Caution The appearance of the IHB icon indicates that a pulse irregularity consistent with an irregular heartbeat was detected during measurement Usually this is NOT a cause for concern If the symbol appears often you should seek medical advice This device does not replace a c...

Page 23: ...reading I get at the doctor s different Blood pressure readings vary best on conditions as described above and just being in the hospital or the doctor s office can raise your blood pressure causing your reading to be higher Does it matter which wrist I use You can take a measurement on either wrist though most medical professionals normally want to take your pressure on the left side Whichever wr...

Page 24: ...ve Relax for a moment then measure again E10 or E11 Shows The monitor detected motion while measuring Movement can affect the measurement Relax then measure again E20 Shows The measurement process does not detect the pulse signal Loosen clothing on the arm and them measure again E21 Shows Measure incorrectly Relax for a moment and then measure again EExx shows on the display A calibration error oc...

Page 25: ...re 4 F to 140 F 20 C to 60 C RH 10 to 93 Atmospheric pressure 50kPa to 106kPa Measurement perimeter of the wrist Approximately 5 3 in 8 5 in 13 5 cm 21 5 cm Net Weight Approximately 0 24 pounds 110 grams External dimensions Approx 3 14 in x 2 85 in x 0 52 in 79 8 72 5 13 2mm Attachment USB Cable and user manual Mode of operation Continuous operation Degree of protection Type BF applied part Protec...

Page 26: ...r basic safety and essential performance Electromagnetic compatibility IEC EN 60601 1 2 2007 Medical electrical equipment Part 1 2 General requirements for basic safety and essential performance Collateral standard Electromagnetic compatibility Requirements and tests Performance and clinical requirements IEC 80601 2 30 2009 Medical electrical equipment Part 2 30 Particular requirements for the bas...

Page 27: ... regarding EMC and needs to be installed and put into service according to the EMC information provided in the ACCOMPANYING DOCUMENTS 2 Wireless communications equipment such as wireless home network devices mobile phones cordless telephones and their base stations walkie talkies can affect this equipment and should be kept at least a distance d 3 3 m away from the equipment Note As indicated in T...

Page 28: ... a Return Merchandise Authorization number RMA and return instructions proof of purchase is required Products returned without a Vitasigns generated RMA number will not be accepted and the sender will not receive a refund replacement or repaired product info vitasigns com 1 888 824 2424 31 East MacArthur Crescent Suite 111 Santa Ana CA 92707 vitasigns com There are no express warranties except as ...