Vita Spa xStream Owner'S Manual Download Page 13

 

3s 

TO START 

SELF TEST 

TO CANCEL 

SELF TEST 

continues  

on next 

page 

Turns filtration On/Off 
on shown hour. 

12: -

 Off 

12: F

 Filtering 

Cycles up through 

filtration hours 

USE ARROWS 
TO CHANGE 
BETWEEN 

MODES 

FACTORY DEFAULTS 

 12: - 

AM

 12: 

-

 PM

 

  1: - 

1: -

 

  2: - 

2: -

 

  3: - 

3: -

 

  4: - 

4: F

 

  5: - 

5: F

 

  6: - 

6: -

 

  7: - 

7: -

 

  8: F 

8: - 

  9: F 

9: - 

  10: - 

10: - 

  11: - 

11: -

 

 

THERAPY PROGRAMMING INSTRUCTIONS 

REFER TO PROGRAMMING INSTRUCTIONS ON PAGE 21 FOR QUICK PROGRAMMING STEPS 

 

 

A. PROGRAMMING MENU .....................................................  

Note: All programming functions are shown sequentially. To access any 
specific programming step, you have to enter programming from the 
beginning, as explained here. 

Press and hold 

 for three (3) seconds until 

“dISC”

 is on the screen to 

enter the programming menu.  

To exit programming mode, press 

 or 

 at any point in the 

sequence or wait for 10 seconds (without pressing any button). 

B.  SELF - DIAGNOSTIC TOOL  ...............................................  

Note: This feature is operational on all Control Boards Rev J and up. 

Your spa controller offers the latest state-of-the-art diagnostic tool. To start 
the test, press 

 while the display is showing 

"diSC"

. This test will run the 

equipment sequentially for two (2) minutes. To cancel the self-test at any 
time, press 

. Once the test is completed, the message 

"good"

 will be 

displayed if your spa operates properly. If a problem is found, the malfunction 
code will be displayed. Please contact your dealer for corrective action. 

C. HEATING  ..........................................................................  

Your spa is pre-programmed from factory to run on 

AutoHeat

 mode every day 

of the week. That means whenever the temperature of the water falls 1ºF 
(0.5ºC) below the set temperature, the ICS

TM

 control will start the heating cycle 

and run it until the temperature reaches 1ºF (0.5ºC) above the set temperature. 

Note: Refer to Section E. HEAT DAYS & TEMPERATURE for how to change this setting. 

To save even more, you may switch it to 

ECONOMY

 mode, where the heating cycle 

will only come on during programmed filtration hours. (See “Filtration Cycle” below). 

Note: In ECONOMY mode, if at the end of filtration cycle the water has not reached the 
set temperature, the heating cycle will stop. This mode is used for energy conservation, 
the same way you would control your heat or air conditioning in your house. 

D. FILTRATION CYCLE ..........................................................  

Your spa is pre-programmed from the factory to run the filtration cycle for 
two hours in the morning and two hours in the evening. It is recommended 
that filtration hours be set to the minimum necessary to maintain water 
quality. 

Notes:  Please review this setting upon installation. 

Some Control Boards programmed for AH may jump the filtration hours 
setting. If that happens, change from AH to ECO, program the desired filtration 
hours and change back to AH. 

During filtration, the water temperature may rise slightly, therefore 
to prevent overheating during the warmer months of the year, do not 
program filtration for more than 6 hours a day (4 hours in very hot 
climates). 

Keeping your set temperature a few degrees below your desired 
temperature will aid in controlling water temperature. 

PAGE 7

Summary of Contents for xStream

Page 1: ...mi Florida 33054 www dmindustries com h e a l t h a n d r e l a x a t i o n f o r l i f e IMPORTANT SAFETY INSTRUCTIONS READ ENTIRE MANUAL BEFORE INSTALLING SPA PLEASE SAVE THIS MANUAL OWNER S MANUAL...

Page 2: ...TO CAN CSA C22 2 STD NO 218 1 DM Industries LTD 2350 N W 147 Street Miami FL 33021 305 685 5739 www dmindustries com Serial Number Model Number ID PLATES ARE LOCATED IN THE FRONT OF THE SPA A SMALL I...

Page 3: ...____ ADDRESS ________________________________________________ ___________________________________________________________ TELEPHONE ______________________________________________ SERIAL ______________...

Page 4: ......

Page 5: ...or the Day 11 Badu Stream Jets II 11 V Stream Jets 11 Operating the Lights 12 Programming AquaBrite Chromatherapy 12 Operating the Stereo 12 SWIM OPERATION continued Swim Programming Instructions 13 S...

Page 6: ......

Page 7: ...nded for young children and when spa use exceeds 10 minutes B Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibl...

Page 8: ...e cover on Extended hi speed pump operation will cause a slow heat build up due to water friction which could trip the spa s hi limit thermostat DO NOT DIVE INTO SPA SAVE THESE INSTRUCTIONS SITE SELEC...

Page 9: ...t all times when not in use DANGER RISK OF INJURY To reduce the risk of potential injury 1 Never leave a spa uncovered or unattended 2 Never leave a spa cover unlocked 3 Do not stand sit or lie on the...

Page 10: ...817G2 817G1 817G3 2 ea 0212318 2 ea 0532064 Cascade Cover Plate 0663005 1 ea 0212305 TRB 2 ea 0532064 1 ea 0212318 2 ea 0212318 DRAIN DRAIN DRAIN DRAIN PAGE 4 NO DIVING TILES...

Page 11: ...tened water Never fill the spa entirely with softened water GFCI The GFCI is a very important safety device and the National Electric Code requires that all spas are GFCI protected The GFCI shuts off...

Page 12: ...or in heating mode it will immediately restart running at low speed to filtrate and or heat the water This button controls the LED lights The first press turns the underwater light on Second press tur...

Page 13: ...ry to run on AutoHeat mode every day of the week That means whenever the temperature of the water falls 1 F 0 5 C below the set temperature the ICSTM control will start the heating cycle and run it un...

Page 14: ...to cycle through the program until the display shows hd A again Then repeat steps 1 through 3 to do the same for Wednesday hd 4 Tuesday hd 3 and Monday hd 2 NOTE If you programmed different temperatu...

Page 15: ...o follow button commands incorrectly A3 POWER SERVICE LEVEL The Therapy side of the xStream Duo Pro should be set to S 0 ONLY This indicates that the heater will shut off when the pump is turned on hi...

Page 16: ...ef description of each button is as follows Button Not active Pressing this button will cycle the therapy jets through a soothing soaking mode to an invigorating therapy mode and then off Not active P...

Page 17: ...d creates a unique invigorating bubble bath effect It will also add additional resistance to swim against BADU STREAM II s adjustable flow nozzle enables swimmers to regulate the volume of water relea...

Page 18: ...Colors Red Blue L 10 Music Stereo must be on to work The lighting system will automatically turn itself off after three 3 hours SURROUND STEREO OPTIONAL The stereo option allows you to listen to FM s...

Page 19: ...how the heat day Press again until the desired heat day is selected 2 Press to display temperature for the day selected Press and hold to lower temperature to for instance to 80 F 27 C Press to increa...

Page 20: ...ess to remove the Heat Lock of the heater Notice that the lock icon will disappear All spa functions including temperature adjustment will be accessible G PANEL LOCK The ICSTM controller also allows y...

Page 21: ...uld be set to S 0 ONLY This indicates that the heater will shut off when any pump is turned on high speed except for the filtration circulation pump Warning Changes to this setting may cause inadverte...

Page 22: ...For cleaning purposes these jet faces can be removed by grabbing outer face and pulling away from jet body Re install it by pushing the face back in place B DIRECTIONAL MASSAGE JETS When the pump is...

Page 23: ...If you cannot pinpoint the cause Call Your Dealer for technical assistance C OVERHEAT PROTECTION If a malfunction occurs and the spa water temperature reaches 44 5 C 112 F the pump and heater will tu...

Page 24: ...id the surface warranty of the spa COVER MAINTENANCE Your cover is manufactured from a durable marine grade UV resistant material Even so monthly cleaning and periodic con ditioning is recommended to...

Page 25: ...s properly evacuated this is not nec essary 3 Loosen and remove the union connections to your spas heater and pumps this will allow standing water in these components to further drain 4 To further ens...

Page 26: ...ll Electrician if it will not start Clean change filter element see page 4 for filter part numbers Check pump for flow on therapy side check low speed running On swim side check circ pump running If F...

Page 27: ...k Programming Instructions or Prime cycle at startup P Yes No Notice When set to P Pr pumps run for 2 minutes every time power is fed to the spa U US E Europ e Switches clock between 12h and 24h Clock...

Page 28: ...Rev Date 10 9 2008 Not Applicable should be set to b Power Service Level MUST BE S 0 DO NOT CHANGE Warning Changes to this setting may cause inadvertent breaker tripping and strain your power connect...

Page 29: ......

Page 30: ...JECT TO CHANGE WITHOUT NOTICE DM Industries Ltd 2320 Northwest 147th Street Miami Florida 33054 Email customercare dmindustries com and techhelp dmindustries com www dmindustries com MIAMI FLORIDA DM...

Reviews: