![visual engineering MFR-DB User Manual Download Page 12](http://html1.mh-extra.com/html/visual-engineering/mfr-db/mfr-db_user-manual_1034015012.webp)
visualengineering.co.uk
Page 12
MFR-DB
December 2021
Through the camera’s serial comms path the thermal camera module can be controlled using
standard FLIR protocol, which is wrapped using the following custom VISCA command/response�
The payload of the command/response is the standard FLIR command�
8[x]
0x01
0x04
0x24
0x9F
0x01
[a]
[b]
0xFF
Flir Pass Through
[x]
= The Unit Address, which can be set in the
[a]
= Payload Length
[b]
= Standard Flir Command Payload, variable length
Send Command
[y]0
0x41
0xFF
Response Acknowledge
[y]
= The Unit 8�
[a]
= Payload Length
[b]
= Standard Flir Command Payload, variable length
Response Complete
[y]0
0x51
0x24
0x9F
0x01
[a]
[b]
0xFF