V1629 

 

DUAL MONITORING ENCODER 

 
 
 
 
 
 

INSTALLATION and OPERATION

 

 
 
 
 
 
 
 
 
© Vistek Electronics Ltd 
 
 
Filename: V1629om.doc 
Issue: A 
Date: December 

2000 

 
 
 
 
 

VISTEK Electronics Ltd 
Wessex Rd 
Bourne End 
Buckinghamshire,  SL8 5DT 
ENGLAND 

 

Tel.  

+44 1628 531221 

Fax. 

+44 1628 530980

 

Web: www.vistek.tv

Summary of Contents for V1629

Page 1: ...AL MONITORING ENCODER INSTALLATION and OPERATION Vistek Electronics Ltd Filename V1629om doc Issue A Date December 2000 VISTEK Electronics Ltd Wessex Rd Bourne End Buckinghamshire SL8 5DT ENGLAND Tel...

Page 2: ...M Which standard is used can be set locally on a DIL switch on the PCB or remotely over the DART remote control system The two channels are quite independent and can be operating in either the same or...

Page 3: ...RCE COMMENTS POWER The Rack 7 5W SDI A I P SD IN Sourcing cable length up to 200m SDI A O P Reclocked version of SDI A Driving cable length up to 200m CVBS A1 Colour Composite or Y Channel A CVBS or Y...

Page 4: ...e FLEX device U20 FRONT PANEL REAR CONNECTOR PROM SW1 U27 FS1 1 8 U16 uP A SW2 1 8 U28 uP B VR1 VR2 VR3 VR4 VR5 VR6 on off off on 2 4 ADJUSTMENTS The drawing in section 2 3 shows 6 variable resistors...

Page 5: ...to CVBS 3 DR Off Dynamic Rounding disabled Dynamic Rounding ON 4 NTSC Japan NTSC JAPAN for 525 60 i ps Standard NTSC for 525 60 i ps 5 unused 6 unused 7 PLUGE Disable PLUGE not selectable PLUGE avail...

Page 6: ...nt panel indication whether it is standard NTSC or the Japanese variant which has no setup 3 2 4 TEST SIGNAL The normal Test Signal available is PLUGE and this is used in all other parts of this manua...

Page 7: ...60 NTSC 2 VI Blank 625 623 5 22 311 335 625 623 5 6 311 320 525 1 20 263 5 19 525 1 9 263 5 9 3 DR Off Dynamic Rounding disabled Dynamic Rounding ON 4 NTSC Japan 625 no effect 625 no effect 525 NTSC...

Page 8: ...uch as the V1608 The DART map of all available controls is shown in section 3 12 3 7 PLUGE PLUGE is a monochrome test signal to assist in the setting up of picture monitors It contains two parts low l...

Page 9: ...there will be no output All analogue outputs are switched off to a dc level For the Coder outputs this is in the region of the sync tips approximately 300mV For the YC outputs if selected the dc volt...

Page 10: ...ng at the C output with the unit set to YC Wrong colour standard Set incorrectly on the DIL switch or over DART Wrong level in NTSC Probably caused by the unit being set to Japanese NTSC on the intern...