2.2
VELOCITY, SLOW V and SLOW V RATE
VELOCITY
Axis moves at 0 to 100% of maximum axis speed based on how fast the MPG
wheel is turned.
SLOW V
Pressing and holding the EN side button while in V mode temporally slows down
the axis movement .
SLOW V RATE
Double clicking and holding the EN side button and turn MPG clockwise or
counterclockwise to change V slow down rate. Settable number: 2, 3 and 4.
2.3
CONTINUOUS, CONTINUOUS RATE
CONTINUOUS
In CONTINUOUS mode, axis moves at constant speed of continuous rate
set in CONTINUOUR RATE mode.
□
Continuous rate
CONTINUOUS RATE
Pressing and holding the EN side button to change to C% mode. In
C% mode, turning MPG changes the speed used in CONTINUOUS
mode.
2.4 FEED OVERRIDE
and