VISSONIC Electronics Limited
Page 21
and sign-in (sign-in via IC card can be set).
4.3 Dual 64-channel selector software module
(software license model: VIS-ALGE)
Enter the host menu "Interpretation" to set relevant parameters of the interpretation unit. Select the number of
channels to be opened, the corresponding language of the channel, and the serial number of the interpretation
booth.
Menu item
Parameter
Parameter value
Description
Max. channel
-
00 to 64
Set the number of interpretation channels according
to the conference demands to simplify channel
selection on the unit.
Channel
00
01
...
64
Chinese,
English...
(104 languages)
Chinese,
English...
(104 languages)
Chinese,
English...
(104 languages)
Bind the language for each channel. The number of
microphone channels can be selected according to
the number of languages to be interpreted. The
corresponding number of channels can be set on the
host to bind the corresponding languages.
Auto floor
-
On/Off
On - When the interpretation unit turns off the
microphone to stop interpretation, the channel that the
interpretation unit is responsible for automatically
switches to the original sound of the channel.
Off - When the interpretation unit turns off the
microphone to stop interpretation, the channel that the
interpretation unit is responsible for has no audio output.
Channel lock
On/Off
On - The output channel of the interpretation unit is
locked, and the interpreter cannot change it randomly.
Off - The output channel of the interpretation unit can be
set by the interpreter.
Booth setup
Max. booth
Start set
02 to 64
On/Off
Max. booth - Sets the number of interpretation booths.
On - Start setting. All interpretation units display the
booth No., which can be changed by pressing the speech
key. The booth No. of interpretation units in the same
booth must be the same.
Off - Complete setting.
Function - When the microphone of any interpretation
unit is turned on, the loudspeaker of interpretation units in
the same booth will automatically be turned off.