background image

Step Two

THE JASPER

FLIP THE FOUR TRUSS FRAME LENGTHS OVER AND LAY THEM OUT

TO FORM A SQUARE.

ATTACH THE CORNERS TOGETHER AS SHOWN IN DIAGRAM 1.

FASTEN ALL FOUR CORNERS IN THE SAME FASHION.

DIAGRAM 1

MEASURE THE TRUSS FRAME TO VERIFY SQUARENESS.

THE MEASUREMENT FROM "A" TO "D" MUST EQUAL "B" TO "C".

ADJUST THE TRUSS FRAME UNTIL BOTH MEASUREMENTS
ARE EQUAL.

A TO D = B TO C

2 1/2" ROBERTSON SCREWS 

12 req

THE TRUSS FRAME ASSEMBLY MUST BE SQUARE

TRUSS FRAME LENGTH

TRUSS FRAME LENGTH

TRUSS FRAME LENGTH

TRUSS FRAME LENGTH

0097_Jasper_11x11_Instructions_V1.2

TOLL FREE: 1-877-795-7423

B

EN

Summary of Contents for JASPER 0097

Page 1: ...DOOR WINDOW WINDOW WINDOW 10 81 2 326 cm 10 8 1 2 326 cm 11 103 4 363 cm 11 10 3 4 363 cm 9 4 1 16 285 cm WINDOW Footprint Plan Front Elevation JASPER CODE 0197 TOLL FREE SANS FRAIS 1 877 795 7423 INSTRUCTIONS 0097_Jasper_11x11_Instructions_V1 2 CODE 0097 EN ...

Page 2: ......

Page 3: ...6 4X 1681 3 1 3 0 4X 1571 5 2 4X 4X 4X 4X 1X 4 10 4 10 3 6 3 6 3 7 1855 1853 1854 1856 1842 1304 1042 1351 1352 4X 4X 4X 4X 2 10 6 7 7 2 6 6 0097_Jasper_11x11_Instructions_V1 2 JASPER CODE 0197 PAGE OF DE TOLL FREE SANS FRAIS 1 877 795 7423 MEASUREMENTS ARE APPROXIMATE MESURES SONT APPROXIMATIVES CODE 0097 TRUSS FRAME FERME DE TOIT ROOFING TOITURE PANELS PANNEAUX ...

Page 4: ......

Page 5: ...RDWARE 0097_Jasper_11x11_Instructions_V1 2 CODE 0097 A 1 1 2 8 FLAT HEAD 2 ROBERTSON 12X B 2 1 2 8 FLAT HEAD 2 ROBERTSON 157X C 3 1 2 10 FLAT HEAD 2 ROBERTSON 24X L 2 1 2 SCREW 8 HEX HEAD 1 4 HEAD 4X M 3 SCREW 8 HEX HEAD 1 4 HEAD 32X 2 1 2 PAN HEAD ROBERTSON SCREWS 2 ROBERTSON F 80X 1 1 2 10 ROOF SCREW 1 4 HEAD WITH POLYZIP WASHER J 16X REQUISES AVEC RONDELLES POLYZIP I 1 10 METAL ROOF SCREW 1 4 H...

Page 6: ......

Page 7: ...SSEMBLY TIME 6 HOURS IF YOU REQUIRE ASSISTANCE OR NEED TO ORDER REPLACEMENT PARTS CONTACT YOUR VISSCHER DEALER FOR ADDITIONAL INFORMATION PLEASE CALL THE NUMBER BELOW PLEASE HAVE SERIAL NUMBER READY TO ENSURE QUICK SERVICE BEFORE YOU BEGIN THESE INSTRUCTIONS MUST BE FOLLOWED STEP BY STEP DEVIATION FROM THE INSTRUCTIONS MAY VOID THE PRODUCT S WARRANTY SEE WARRANTY SHEET FOR FURTHER DETAILS READ ALL...

Page 8: ......

Page 9: ...1352 AND ONE LEFT TRUSS FRAME PIECE DC 1351 THE COMPONENTS SHOULD BE FIT AS TIGHTLY TOGETHER AS POSSIBLE REPEAT TO BUILD A TOTAL OF FOUR TRUSS FRAME LENGTHS 3 1 2 ROBERTSON SCREWS 24 req DC 1351 DC 1352 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 C EN ...

Page 10: ...ON DIAGRAM 1 MEASURE THE TRUSS FRAME TO VERIFY SQUARENESS THE MEASUREMENT FROM A TO D MUST EQUAL B TO C ADJUST THE TRUSS FRAME UNTIL BOTH MEASUREMENTS ARE EQUAL A TO D B TO C 2 1 2 ROBERTSON SCREWS 12 req THE TRUSS FRAME ASSEMBLY MUST BE SQUARE TRUSS FRAME LENGTH TRUSS FRAME LENGTH TRUSS FRAME LENGTH TRUSS FRAME LENGTH 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 B EN ...

Page 11: ... ONCE BRACES ARE ATTACHED LAY THE SQUARED TRUSS FRAME ASSEMBLY AT THE EXACT LOCATION YOU WISH YOUR GAZEBO TO BE USING A PENCIL OR MARKER TRACE THE OUTSIDE EDGES OF ALL FOUR CORNERS ONTO THE GROUND THESE MARKINGS WILL BE HELPFUL IN PLACING YOUR CORNER POSTS AND PANELS IN THE STEPS TO COME ONCE MARKINGS ARE COMPLETE MOVE THE TRUSS FRAME UP AND OUT OF THE WAY MAKE REFERENCE MARKS DC 1304 DC 1304 DC 1...

Page 12: ...IF YOU HAVE PURCHASED AN OPTIONAL BAY WALL KIT FOR YOUR OUTDOOR STRUCTURE PLEASE MOVE ON TO STEP ONE OF THE INSTRUCTIONS PROVIDED WITH THE BAY KIT AT THIS TIME OPTIONAL BAY KIT ...

Page 13: ...OUTSIDE OF THE POST AND FLUSH AT TOP AND BOTTOM IF YOU WANT THE DOOR TO BE LOCATED TIGHT TO A CORNER SUBSTITUTE A WALL PANEL FOR THE DOOR PANEL DC 1970 MOVE ALL FOUR ASSEMBLIES TO THE GROUND REFERENCE MARKERS FROM STEP THREE DC 1971 DC 1971 DC 1042 2 1 2 BLACK PAN HEAD ROBERTSON SCREWS 32 req 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 F EN ...

Page 14: ...ND THE DOOR PANEL DC 1970 CONTINUE THE SAME SCREW PATTERN FROM THE PREVIOUS STEP WALL PANELS ARE TO BE FLUSH WITH EACH OTHER AND FLUSH AT TOP AND BOTTOM DC 1971 DC 1971 DC 1971 DC 1970 REFERENCE MARK REFERENCE MARK REFERENCE MARK REFERENCE MARK 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 F EN ...

Page 15: ...TH THE OUTSIDE OF THE TRUSS FRAME ASSEMBLY SCREW DOWN THROUGH THE PLATE OF THE TRUSS FRAME ASSEMBLY INTO THE TOP OF EACH WALL AND DOOR PANEL USE THREE SCREWS PER WALL PANEL AND FOUR PER DOOR PANEL SECTION VIEW 2 1 2 ROBERTSON SCREWS 37 req FLUSH TRUSS FRAME OUTSIDE WALL PANEL OUTSIDE 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 B EN ...

Page 16: ...THE SKYLIGHT FRAME USING FOUR SKYLIGHT PIECES DC 1681 IT IS IMPORTANT TO CHASE CORNERS AS SHOWN BELOW DC 1681 DC 1681 DC 1681 DC 1681 2 1 2 ROBERTSON SCREWS 12 req 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 B EN ...

Page 17: ...DC 1675 TO THE SKYLIGHT FRAME CENTRED ON EACH SIDE THE BOTTOM EDGE OF THE RAFTERS ARE TO BE FLUSH WITH THE BOTTOM OF THE SKYLIGHT FRAME 3 HEX HEAD SCREWS 8 req DC 1675 DC 1675 DC 1675 DC 1675 DC 1675 DC 1675 FLUSH FLUSH SECTION VIEW 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 M EN ...

Page 18: ...T FRAME AND RAFTER ASSEMBLY OVER AND PLACE ON TRUSS FRAME CENTRE THE RAFTERS ON THE TRUSS FRAME DO NOT FASTEN RAFTERS TO THE TRUSS FRAME AT THIS TIME SECTION VIEW TOP PLAN VIEW 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 EN ...

Page 19: ...HE JASPER 3 HEX HEAD SCREWS 8 req SECTION VIEW TOP PLAN VIEW ATTACH HIP RAFTERS DC 1676 THE BOTTOM EDGE OF THE RAFTER IS TO BE FLUSH WITH THE BOTTOM EDGE OF THE SKYLIGHT FRAME D C 1 6 7 6 D C 1 6 7 6 D C 1 6 7 6 D C 1 6 7 6 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 M EN ...

Page 20: ...ANEL SUPPORTS DC1570 DC1571 TO THE TRUSS FRAME DC 1570 2 1 2 ROBERTSON SCREWS 32 req FLUSH DC 1571 DC 1571 DC 1570 DC 1570 DC 1570 DC 1571 SECTION VIEW FLUSH 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 B DC 1570 DC 1571 DC 1571 EN ...

Page 21: ...LIGHT FRAME FASTEN THE LONG ROOF STRAPPING DC 1244 TO THE RAFTERS AND TIGHT TO THE RAFTER BLOCK THE ANGLE CUTS ARE TO BE FACE DOWN AND LOCATED AT THE HIP RAFTERS DC 1758 DC 1758 DC 1758 DC 1758 DC 1244 DC 1244 DC 1244 DC 1244 DO NOT STAND ON THE TRUSS FRAME OR RAFTER ASSEMBLY 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 B RAFTER BLOCK SKYLIGHT FRAME EN ...

Page 22: ...EWS 16 req SECURE THE RAFTERS TO THE TRUSS FRAME SECURE THE COMMON RAFTERS AS SHOWN IN DETAIL 1 DETAIL 1 DETAIL 2 SECURE THE HIP RAFTERS AS SHOW IN DETAIL 2 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 M DETAIL 1 DETAIL 2 EN ...

Page 23: ...IF YOU HAVE PURCHASED AN OPTIONAL BAY WALL KIT FOR YOUR OUTDOOR STRUCTURE PLEASE MOVE ON TO STEP THREE OF THE INSTRUCTIONS PROVIDED WITH THE BAY KIT AT THIS TIME OPTIONAL BAY KIT ...

Page 24: ...ERSIDE OF THE ROOFING SHEETS CLOSURE TABS ARE TO BE IN LINE WITH THE FIRST ROW OF PUNCHED SCREW LOCATIONS TRIM CLOSURE TABS FOR NARROW ROOF PANELS SECTION VIEW DC 1834 CLOSURE TAB DC 1834 ROOFING SHEET 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 EN ...

Page 25: ...L OVER THE ENTIRE EAVE FASTEN THROUGH PRE PUNCHED HOLES ONLY REPEAT FOR THREE SIDES OF THE ROOF AT THIS TIME 1 ROOF SCREWS 120 req TIGHT TO THE OUTSIDE EDGE OF SKYLIGHT FRAME ONLY NOT ON TOP OF THE FRAME TIP FASTEN ROOFING SHEETS ONLY ON THREE SIDES OF THE ROOF AT THIS TIME THIS WILL MAKE FOR EASIER MOUNTING OF THE SKYLIGHT IMPORTANT FASTEN ALL SCREWS PRIOR TO STEPPING ON ROOF 0097_Jasper_11x11_In...

Page 26: ...Step Sixteen THE JASPER ASSEMBLE THE SKYLIGHT DC 1840 1841 2 1 2 HEX HEAD SCREWS 4 req 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 L EN ...

Page 27: ...Step Seventeen THE JASPER FASTEN FOAM WEATHER GASKET DC 1850 TO THE PERIMETER OF THE SKYLIGHT ALONG THE INSIDE EDGE DC 1850 TRIM AS NEEDED 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 EN ...

Page 28: ...ILLED HOLES OF THE SKYLIGHT FRAME DC 1842 1 1 2 10 METAL ROOF SCREW 1 4 HEAD WITH POLYZIP WASHER 2 req 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 J THE ACRYLIC PANEL EXPANDS AND CONTRACTS AT A DIFFERENT RATE THAN THE SKYLIGHT FRAME IF THE SHANK OF THE SCREW IS TIGHT AGAINST THE ACRYLIC PANEL CRACKING WILL OCCUR TAKE THE NECESSARY TIME TO PROPERLY CENTRE EACH SCREW SCREWS MUST BE ...

Page 29: ...D WITH POLYZIP WASHER 14 req 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 J THE ACRYLIC PANEL EXPANDS AND CONTRACTS AT A DIFFERENT RATE THAN THE SKYLIGHT FRAME IF THE SHANK OF THE SCREW IS TIGHT AGAINST THE ACRYLIC PANEL CRACKING WILL OCCUR TAKE THE NECESSARY TIME TO PROPERLY CENTRE EACH SCREW SCREWS MUST BE CENTRED IN HOLES EN ...

Page 30: ...q PLACE THE SKYLIGHT ASSEMBLY INTO POSITION ON TOP OF THE SKYLIGHT FRAME FASTEN THE SKYLIGHT ASSEMBLY TO THE SKYLIGHT FRAME FROM THE INSIDE USE THREE SCREWS ON ANGLE PER SIDE SECTION VIEW 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 A EN ...

Page 31: ...F THE ROOF MIDDLE SHEETS ARE TO BE TIGHT TO THE OUTSIDE EDGE OF THE SKYLIGHT FRAME AND BENEATH THE SKYLIGHT FLASHING THE OVERHANG IS TO BE EQUAL OVER THE ENTIRE EAVE FASTEN THROUGH PRE PUNCHED HOLES ONLY 1 ROOF SCREWS 40 req IMPORTANT FASTEN ALL SCREWS PRIOR TO STEPPING ON ROOF 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 I EN ...

Page 32: ...wo THE JASPER 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 CAREFULLY PEEL THE BACKER AND PLACE THE SEALING TAPE DC 2033 UNDER THE SKYLIGHT FRAME FLASHING AS SHOWN IN DETAIL 1 SEALING TAPE DC 2033 EN ...

Page 33: ...THE SEALING TAPE DC 2033 OVER TOP OF THE JOINT BETWEEN THE ROOFING SHEETS APPLY PRESSURE TO ADHERE THE TAPE TO THE CONTOUR OF THE ROOFING SHEETS ONCE ADHERED FULLY TRIM AT EDGE OF THE ROOFING SHEET AS SHOWN IN DETAIL 1 REPEAT THIS ON ALL FOUR SIDES DETAIL 1 THE SEALING TAPE MUST BE CENTERED ON THE JOINT CENTRED ON JOINT EN ...

Page 34: ...CH CAP SO THAT THE TOP OF THE CAP FITS TIGHT INTO THE CORNER OF THE SKYLIGHT FRAME UNDER THE SKYLIGHT FLASHING MAKE SURE THAT THE CAP IS SITTING CENTRED ON THE HIP THEN ATTACH IT THROUGH THE ROOFING SHEET AND INTO THE STRAPPING SCREWS MUST BE FASTENED THROUGH THE TOP RIBS OF THE ROOFING SHEET ONLY DO NOT OVER TIGHTEN OR THE HIP CAPS MAY BE DAMAGED SCREWS MUST BE FASTENED THROUGH THE TOP RIBS OF TH...

Page 35: ...IF YOU HAVE PURCHASED AN OPTIONAL BAY WALL KIT FOR YOUR OUTDOOR STRUCTURE PLEASE MOVE ON TO STEP SEVEN OF THE INSTRUCTIONS PROVIDED WITH THE BAY KIT AT THIS TIME OPTIONAL BAY KIT ...

Page 36: ...AL BAR INTO THE THUMB BUTTON SLIDE THE SPRING OVER THE FLAT METAL BAR PRESS THIS ASSEMBLY AGAINST THE DOOR AT THE THREE HOLES FIT THE LATCH TO THE OPPOSITE SIDE OF THE DOOR USING A SCREWDRIVER TIGHTEN THE ASSEMBLY TO THE DOOR ATTACH THE BOTTOM OF THE HANDLE USING A SMALL SCREW DISCARD ALL REMAINING HARDWARE FROM THE PACK 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 EN ...

Page 37: ...Step Twenty Six THE JASPER INSTALL SCREEN FRAMES DC 1747 INTO THE WALL PANELS TURN CLIPS TO LOCK THE SCREEN FRAME IN PLACE 0097_Jasper_11x11_Instructions_V1 2 TOLL FREE 1 877 795 7423 EN ...

Page 38: ......

Reviews: