background image

3

Xero L P/L

349-060.19

349-061.19

red

6.

1

0.240"

4.2

0.165"

349-140.19 (90 W)

NV (24 V)

L = 500 mm

 / 19.685"

ø 

7.7 mm

0.303"

120 V

=

 

1500 mm

 / 59.055“

1/2019 (US)

Xero L P/L has a CE label and a UL certificate for U.S. and Canada.

Converter 24 V for electrified profile

Converter with input voltage 120–240 V / mains frequency: 50–60 Hz electronic protection 

against overload, overheating and short-circuit.
- Housing temperature max. 75 °C / max. 167 °F
- Nominal output voltage: 24 V / SELV
- Power supply with permissible nominal current of max. 4 A
- Connection cable from converter to infeed unit 

500 mm

/19.685“ 

- Class 2
NOTICE! If dimmers are to be used, electronically controlled, low-voltage dimmers must be 

installed!

Single power adapter 24 V

Single power adapters can be used with the Xero L P/L and Xero Twin P/L systems. Low 

voltage lighting may only be connected by trained personnel.
If multiple adapters and appliances will be used, their total power consumption may not 

exceed the specified nominal current or fuse rating. The permissible nominal voltage and 

nominal current are also limited according to the adapters used (see printed label and safety 

information).
Permissible nominal current max. 4 A.

 Please make sure that the inspector has access to the driver

TECHNICAL DATA SHEET XERO L P/L

Xero L P/L electrification in detail: conductor rail with power supply, integrated into system support profile.
Correct functioning and safety are guaranteed when properly used. No liability is accepted in event of improper use. Product safety 

is based exclusively on the use of original Xero L P/L and Xero Twin P/L accessories from Visplay. 

No alterations may be made, for safety reasons; the only exception is the shortening of profiles from the right-hand side. 

The safety instructions of the assembly instructions must be followed as well as the instructions on the labels of the individual parts. 

The indicated nominal current (A) may not be exceeded.  

In event of improper use or cleaning with liquids, a risk of an electric shock exists due to possibly exposed live parts. Always 

disconnect from power before cleaning or servicing. 

If rails or adapters exhibit visible signs of damage, disconnect them immediately and inform your service technician.

Product safety

 Only use Xero L P/L and Xero Twin P/L system accessories! Do not use any other parts.

The user is responsible for ensuring that any connected equipment is electrically, mechanically and thermally compatible with the conductor rail.

Summary of Contents for Xero L P/L

Page 1: ...play it smart Xero L P L Assembly and operating instructions USA CANADA ...

Page 2: ... most pronounced more so than with front on horizontal or inclined pole displays where garments are hung side on such that hangers have to be moved more frequently To prevent garments from becoming soiled cleaning of the hanging rods is essential This abrasion can be considerably reduced by using a coat hanger cover scliss 929 449 02 No responsiblity can be accepted for damage caused by soiling as...

Page 3: ...nformation Permissible nominal current max 4 A Please make sure that the inspector has access to the driver TECHNICAL DATA SHEET XERO L P L Xero L P L electrification in detail conductor rail with power supply integrated into system support profile Correct functioning and safety are guaranteed when properly used No liability is accepted in event of improper use Product safety is based exclusively ...

Page 4: ...L 1500 mm 59 055 NV 24 V L 500 mm 19 685 1 2019 US 1 24 V distributor 6 way optional 2 90 W LED converter Check the power consumption of electrical appliances The maximum power consumption should be 10 below the nominal power of the converter Visplay connection system Powering with 90 W converter Dimensions of the 90 W converter ...

Page 5: ...file set electrified Assembly dimensions Layout Xero Twin P L profiles can be screwed in cabinets or on panels The accessories with fixed axis distance from Xero L P L and Xero Twin P L can be used Please observe the indications concerning weight loads and ensure that the substructure of the wall units furniture and their fixtures can support the expected loads With free standing furniture ensure ...

Page 6: ...h of rear panel 606 981 1231 0 5 23 858 38 622 48 465 0 02 Width of rear panel 606 981 1231 0 5 23 858 38 622 48 465 0 02 A 617 5 A 992 5 A 1242 5 24 311 39 075 48 917 A 617 5 A 992 5 A 1242 5 24 311 39 075 48 917 10 5 0 413 10 5 0 413 16 0 630 1 2019 US Assembly dimensions for 2 axis Xero L P L profile set electrified and Xero Twin P L profile electrified The electrical components and the end cap...

Page 7: ...ature of the wall the number of fastening points as well as the fastening material used All fastening points have to be used in event of a maximum weight load Please also observe the weight loads indicated in our sales documentation Wooden shelf for brackets with single power adapter Wooden shelf for brackets For wooden shelf max 1245 mm 49 016 long by max 380 mm 14 961 deep and max 12 W power con...

Page 8: ...m Russia Distributed by ULTIMATHULE Exclusive Dealer Business quartel ARMA Nizhniy Susalniy per 5 bld 18 105065 Moscow Russia T 7 495 988 21 20 visplay ultimathule ru Saudi Arabia Distributed by Saudi TKT Authorized Distributor P O Box 10700 Jeddah 21443 Saudi Arabia T 971 4 321 56 74 visplay dubai visplay com Turkey Distributed by Dekotek Mimarlık Ltd Sti Exclusive Dealer Sair Nigar Sokak 80 8 Os...

Reviews: