FOS | Technical data
18
Visplay GmbH, 07/2022 Edition
7
Technical data
Connected electrical loads
Connection / mains power
230/240 V AC
Frequency
50-60 Hz
Converter protection class
II
System operating voltage
24 V DC
System components protection class III
Maximum power for each power-
feed point
7 A
168 W
8
Weight loads
WARNING
Risk of injury from falling objects and furniture components.
The system can fail if the maximum permissible load on the furniture or individual components is exceeded.
f
Please observe the maximum load value for the individual items of furniture.
f
Do not exceed the maximum load of 30 kg per frame.
The specified weight loads refer to the components listed in the Visplay manual. The maximum weight loads apply with
respect to a uniform load distribution. The load must be reduced immediately if there is visible deflection or deformation of the
components.
Maximum load
Connection frame with support insert
30 kg
Table top
30 kg
Hanging rail
60 kg
TV bracket
50 kg