visplay FOS Instructions For Assembly And Use Download Page 1

Instructions for assembly and use

FOS

Summary of Contents for FOS

Page 1: ...Instructions for assembly and use FOS ...

Page 2: ...Visplay GmbH 07 2022 Edition ...

Page 3: ...orktop between two modules 10 3 4 Connecting multiple structures 11 4 Operation of FOS Media 12 5 Operation of FOS Meet 13 5 1 Assembling table top 13 6 Accessories 14 6 1 Assembling connection frame 14 6 2 Installing reconfiguring furniture 14 6 3 Assembling open closed storage box 15 6 4 Assembling whiteboard pinboard side panels 16 6 5 Assembling wall rail 17 7 Technical data 18 8 Weight loads ...

Page 4: ...r GmbH BSI audits this management system regularly and issues a certificate of compliance with the standard Copyright This manual is protected by copyright Its use is permissible as part of the use of the product Any use other than this is not permitted without the written consent of the manufacturer Our General Terms and Conditions apply for all orders 1 1 Hazard levels indicated by warning notic...

Page 5: ...ly be used in dry indoor areas The FOS modules may be used solely in compliance with the permissible load values see page 18 Any unintended use and unauthorised modification of the furniture shall be deemed as unauthorised misuse that does not fall within the manufacturer s statutory liability limits Misuse Potential sources of danger Unintended use Operation with improperly fitted or inoperative ...

Page 6: ...ING Risk of injury from tipping furniture Furniture can cause serious injuries if it tips over f At least two people must be present when changing components and moving the furniture f The cables must be retracted and stowed before changing components or moving the furniture f Stow cables securely close all doors and remove loose unsecured items before moving the furniture f Release all brakes bef...

Page 7: ...onsists of basic modules that can be combined flexibly with items of equipment and electrically interconnected The individual connection frames can be swapped easily using an SW5 Allen key Schuko Type F USB PD Charger Type C Coupling GST18i3 Non electrified uprights are not fitted with a 24 V power track and are used solely for mechanical connection Electrified uprights are fitted with a 24 V powe...

Page 8: ...or tipping furniture f The unit must be unloaded by two people f Carefully roll the FOS module off the pallet 1 Remove the transport lock 2 Remove all loose parts from the pallet 1 3 Fold down the ramp 2 4 Release the brake on the castors 3 5 Carefully roll the FOS module off the pallet 4 1 3 4 2 2 4 1 3 2 NOTE Hazards to the environment can occur if product components are disposed of improperly f...

Page 9: ... not be modified If you find a damaged component disconnect the structure from the mains and replace the defective component Damaged electrical components must no longer be used f Insert the power plug into a socket 3 2 1 230 V connections The modules can be electrically interconnected This enables you to connect multiple modules to each other using a wall socket EN ...

Page 10: ...lay GmbH 07 2022 Edition 3 2 2 USB PD charging socket type C Devices can be charged at the charging socket via a USB type C connection USB Power Delivery USB PD with max 3 A and 60 W USB PD Charger Type C 3 3 Fitting worktop between two modules ...

Page 11: ...dules when they have been separated and the power plug is disconnected 1 Place the module in the required position 2 Apply the brake on the castors 1 3 Fit a connection frame see Section 6 1 Assembling connection frame on page 14 4 Insert the extension cable 2 into the converter 1 in the FOS module 2 5 Connect the extension cable 2 to the cable on the connection frame 3 1 3 i SW 5 2 i 2 SW 5 1 2 L...

Page 12: ... The fitting is in accordance with the VESA standard W x H of 200 x 200 mm to 1000 x 400 mm in 100 mm increments We recommend using 55 devices 1 Attach the screen mount to fit the size of the device 1 2 Attach the screen mount with the self tapping screws 1 3 Fit the device 2 50mm 100mm max 1500mm max 800mm max 50 kg 200 300 400 mm 1 SW 5 SW 5 2 1 2 ...

Page 13: ...Edition Visplay GmbH FOS Operation of FOS Meet 5 Operation of FOS Meet 5 1 Assembling table top 1 Place the table top on the frame 1 2 Screw the panel to the frame from below with the knurled screws 2 1 2 6x 2 EN ...

Page 14: ...FOS Accessories 14 Visplay GmbH 07 2022 Edition 6 Accessories 6 1 Assembling connection frame 2 3 5 2 SW 5 4 1 6 2 Installing reconfiguring furniture 1 2 3 4 SW 2 SW 5 ...

Page 15: ...ION Risk of injury from falling furniture components f Open closed storage boxes must always be fitted between two frames Tighten the frames with an SW5 Allen key 1 Fit the lower frame 1 2 Insert the storage box 2 3 Fit the upper frame 3 4 Place the shelf on the upper frame 4 1 2 3 4 SW 5 EN ...

Page 16: ...motions Basic clean before first use f Clean the whiteboard with a damp microfibre cloth in circular motions Intensive clean f Clean the whiteboard with a damp microfibre cloth and if required a grease free cleaner using circular motions 1 To use a board a connection frame must be fitted at the height shown 1 2 Hook the board into the upper frame 2 3 Guide the lower part of the board into the lowe...

Page 17: ... Edition Visplay GmbH FOS Accessories 6 5 Assembling wall rail f Fasten the profile rails to the wall with suitable fasteners at 400 mm intervals using the pre drilled holes 1200mm 725mm 1 2 400mm Ø6 mm Ø12 mm EN ...

Page 18: ...stem can fail if the maximum permissible load on the furniture or individual components is exceeded f Please observe the maximum load value for the individual items of furniture f Do not exceed the maximum load of 30 kg per frame The specified weight loads refer to the components listed in the Visplay manual The maximum weight loads apply with respect to a uniform load distribution The load must b...

Page 19: ...ing agent 9 2 Storage Store the product and its components under the following conditions Do not store outdoors Store in a dry and dust free location Protect from sunlight Avoid mechanical shocks Storage temperature 23 C Relative humidity 50 9 3 Disposal NOTE Disposing of product components incorrectly can harm the environment f Ensure product components are disposed of in a proper environmental m...

Page 20: ...www visplay com info visplay com ...