- 3 - 

 
 

CHARGING THE CAPACTITOR 

 

The capacitor must be charged before connecting the Power and Ground 
cables directly. Failure to charge the capacitor will result in a large spark 
generated from the rapid inflow of current. 
 
To Charge the capacitor: 

1.Make your positive terminal connections and tighten the bolt.  
  Caution: Do not over-tighten the bolts! Stripped terminals are 
  not covered under the capacitors warranty. 
 
2. Before connecting the ground cable, place the supplied 
  charging bulb or resistor between the negative terminal on the 
  capacitor and the ground cable. Do this for 60 seconds or until 
  the light bulb goes out. Caution: The charging bulb may get 
  hot!  
 
3.Immediately after charging, connect the ground cable directly 
  to the negative terminal on the cap.

 

display

BULB

CHARGING

)

(

)

(

--

+

BATTERY

 

 
 

 

Summary of Contents for VCAP1F

Page 1: ...ommend you have your new Visonik product installed by an Authorized Visonik Dealer Please read your warranty and retain your receipt and original carton for possible future use To learn more about Vis...

Page 2: ...Table of Contents SPECIFICATIONS 1 INSTALLATION AND MOUNTING 1 BENEFITS OF USING A CAPACITOR 2 CHARGING A CAPACITOR 3 DIS CHARGING CAPACITOR 4 TROUBLESHOOTING 5 WIRING DIAGRAM 5 WARRANTY 6...

Page 3: ...mounted as close to your amplifier s as possible A low resistance connection between the amp and the capacitor is required for maximum performance High resistance connections or long wire lengths redu...

Page 4: ...large amounts of energy in preparation of these bass peaks When a bass peak occurs the stiffening capacitor delivers power to supplement the system voltage and prevent amplifier clipping This retains...

Page 5: ...hten the bolt Caution Do not over tighten the bolts Stripped terminals are not covered under the capacitors warranty 2 Before connecting the ground cable place the supplied charging bulb or resistor b...

Page 6: ...sly display system voltage while system is in use The voltmeter will turn off automatically when the sound system is not in use DISCHARGING THE CAPACITOR To Discharge the capacitor With battery power...

Page 7: ...ged 4 Connect the power wire of the amplifier to an input on the positive distribution terminal block on the Capacitor 5 Connect the power wire from the battery to the capacitor 6 Again do not connect...

Page 8: ...6 Multiple Capacitor Wiring Diagram Note Use a separate ground for the Capacitor as shown in the figure Do not connect the capacitor to the same ground that is used for the amplifiers...

Page 9: ...ent 4 Any product which has had the serial number defaced altered or removed 5 Any product purchased outside the United States 6 Any product not purchased from an Authorized Visonik Dealer Limit on Im...

Reviews: