background image

D-1009-EPS 

Vi-motion, Vi-Pet

 

 

 

English 

PIR / Pet immune Digital Detectors Installation Instructions

 

 

 

Español 

Instrucciones de Instalación de Detectores Digitales PIR / 
Inmume a mascotas 

 

 

Portuguese 

Instruções de instalação de Detectores Digitais PIR / Imune a 
animais 

GB/US: 

Walk-Test LED

SP:

 LED del test de andado

PT:

 LED do teste de passagem

GB/US: 

Lens

SP:

 Lente

PT:

 Lente

 

Fig. 1 - Vi-motion / Vi-Pet 

  

ENGLISH 

1. INTRODUCTION 

The Vi-motion and Vi-Pet (pet immune) are digital PIR detectors, 
designed for easy installation, free of vertical adjustment. They 
include a patented combination of Fresnel and cylindrical optical 
system with high-detection sensitivity beginning at 0.5 meter away 
from the detector up to a distance of 12 meters (40 ft). The detectors 
have full true digital temperature compensation.  
As a pet immune motion detector, the Vi-Pet utilizes TSI™ (Target 
Specific Imaging) technology that ensures immunity to pets weighing 
up to 27 kg (60 lb). 
Advanced 

True Motion Recognition™ 

algorithm (patented)

 

allows the 

detectors to distinguish between true motion of an intruder and other 
disturbances that cause false alarms. An on-board motion event 
selector enables to choose whether 1 or 2 consecutive motion events 
will trigger an alarm. A TST (Test) input permits detector switching to 
walk test mode remotely without opening the detector.  

2. SPECIFICATIONS 

Input Voltage:

 9 to 16 VDC. 

Current Drain:

 Max. 9 mA @ 12 VDC 

OPTICAL

 (see Fig. 2)

 

Lens Data

 

  No. of curtains:

 

Vi-motion:

 46, equivalent to 214 beams. 

Vi-Pet:

 36, equivalent to 196 beams. 

 Max. 

Coverage: 

12 x 12 m (40 x 40 ft) / 90° 

Pet Immunity (Vi-Pet only) :

 Animals up to 27 kg (60 lb) 

ALARM and TAMPER  
Alarm Output: 

Solid-state relay, N.C., up to 100 mA / 30 V,  

~

30 

 internal resistance. Circuit opens for 2-3 seconds upon alarm. 

Alarm Indication: 

LED lights for 2-3 seconds. 

Event Counter:

 Selectable, 1 or 2 motion events. 

Tamper Output

: Normally closed, 50 mA resistive / 30 VDC. 

MOUNTING 

Surface or corner, at the height of 1.8 to 2.4 m (6 to 8 ft) 

Note: 

Base allows single-sided corner mount at 45° to wall. 

ACCESSORIES:  
BR-1:

 Surface mounted swivel bracket, adjustable 30° down and 45° 

left/45° right.  

BR-2:

 BR-1 with a corner adapter.  

BR-3:

 BR-1 with a ceiling adapter. 

ENVIRONMENTAL 
Operating Temperature: –

10°C to 50°C (14°F to 122°F) 

Storage Temperature:

 –20°C to 60°C (–4°F to 140°F) 

RFI Protection:

 Greater than 20 V/m (20 MHz to 1000 MHz) 

Compliance with Standards:

 EN 50131-1 Grade 2, Class II 

PHYSICAL  
Size

 

(H

 

x

 

W

 

x

 

D):

 80 x 50 x 37

 

mm

 

(3-1/8

 

x 1-15/16

 

x

  

1-7/16”) 

Weight:

 Approximately 77 g (2-3/4 oz)

 

PATENTS: 

U.S. Patents 5,693,943 

z

 6,211,522 

z

 6,818,881, 

6,768,294 (other patents pending) 

3. INSTALLATION 

3.1 General Guidance

 

(see fig. 3) 

1. Keep away from heat sources. 
2. Do not expose to air drafts. 

5. Keep wiring away from power 

cables. 

3. Do not install outdoors. 

6. Do not install behind partitions. 

4. Avoid direct sunshine. 

7. Mount on solid stable surface. 

 

3.2 Installation Procedure 

1. Mounting - see fig. 4. 
2. Jumpers settings - see fig. 5. 
3. Wiring – See fig. 6. 

4. Walk-test - see fig. 2. Perform walk across the far end of 

coverage pattern in both directions. The LED should light for 

2-3 seconds each time your motion is detected. 

Important!

 Instruct the user to perform walk test at least once 

a week to verify proper function of the detector. 

 

4. SPECIAL COMMENTS 

4.1 Product Limitations 

Although this detector is a highly reliable device, it does not guarantee 
complete protection against intrusion. Even the most sophisticated detectors 
can sometimes be defeated or may fail to warn because: 

A. 

The detector will not function if the DC power supplied to it is incorrect 

or improperly connected. 

B. 

A PIR detector does not provide full volumetric coverage. It can only 

detect motion that disturbs the sensitive beams spread within the 

protected area.  

C.

  Motion is not detected if it takes place behind closed doors, walls, 

glass partitions, windows and shutters.  

D.

  The detection ability of the PIR detector may be reduced by malicious 

masking or by spraying various materials on the lens or by mechanical 

tampering with the optical system. 

E.

 The PIR detector's performance depends on the temperature 

difference between the environment and the human body. If this 

difference is too small, the PIR performance may decrease. 

F.

  Even the most reliable electrical devices, including this detector, may 

go wrong due to an unexpected failure of a component part. 

The above list includes the most common reasons for failure to detect 

intrusion, but it is by no means comprehensive. It is therefore 

recommended that the detector and the entire alarm system be checked 

weekly, to ensure proper performance. 

An alarm system should not be regarded as a substitute for insurance. 

Home and property owners or renters should be prudent enough to 

continue insuring their lives and property, even though they are protected 

by an alarm system.

 

4.2 Compliance with FCC Standards 

This device has been tested and found to comply with the limits for a Class B 

digital device, pursuant to Part 15 of the FCC Rules. These limits are 

designed to provide reasonable protection against harmful interference in 

residential installations. This equipment generates, uses and can radiate 

radio frequency energy and, if not installed and used in accordance with the 

instructions, may cause harmful interference to radio and television 

reception. However, there is no guarantee that interference will not occur in 

a particular installation. If this device does cause such interference, which 

can be verified by turning the device off and on, the user is encouraged to 

eliminate the interference by one or more of the following measures: 

–  Re-orient or re-locate the receiving antenna. 

–  Increase the distance between the device and the receiver. 

–  Connect the device to an outlet on a circuit different from the one which 

supplies power to the receiver. 

–  Consult the dealer or an experienced radio/TV technician. 

WARNING!

 Changes or modifications to this unit not expressly 

approved by the party responsible for compliance could void the 

user’s authority to operate the equipment.

 

 

 

W.E.E.E. Product Recycling Declaration

 

For  information regarding the recycling  of this product  you must contact 

the  company from which you orignially purchased it. If you are discarding 

this product and not returning it for repair then you must ensure that it is 

returned as identified by your supplier. This product is not to be thrown 

away with everyday waste. 
European Directive 2002/96/EC Waste Electrical and Electronic 

Equipment.

 

 

Summary of Contents for Vi-motion

Page 1: ...struct the user to perform walk test at least once a week to verify proper function of the detector 4 SPECIAL COMMENTS 4 1 Product Limitations Although this detector is a highly reliable device it does not guarantee complete protection against intrusion Even the most sophisticated detectors can sometimes be defeated or may fail to warn because A The detector will not function if the DC power suppl...

Page 2: ... es un dispositivo altamente seguro no garantiza una completa protección frente a intrusión Incluso los detectores más sofisticados pueden ser derrotados a veces o pueden fallar para advertir de A El detector no funcionará si la alimentación de CC suministrada es incorrecto o conectado de forma inapropiada B Un detector PIR no proporciona una cobertura volumétrica completa Sólo puede detectar movi...

Page 3: ...S ESPECIAIS 4 1 Limitações do produto Embora este detector seja altamente seguro não garante uma completa protecção a intrusões Inclusive os detectores mais sofisticados podem ser sabotados e podem mesmo falhar deve ter atenção a A O detector não funcionará se a alimentação CC for incorrecta ou ligada de forma imprópria B Um detector PIR não proporciona uma cobertura volumétrica completa Só pode d...

Page 4: ...eso SP LED de test de andado controlado remotamente por entrada TST Entrada TST conectada a negativo 0 V test de andado activo Entrada TST al aire o conectada a 12 V test de andado desactivado LED apagado PT LED do teste de passagem controlado remotamente pela entrada TST Entrada TST ligada ao negativo 0 V teste de passagem activo Entrada TST em vazio ou ligada a 12 V Teste de passagem desactivado...

Reviews: