1.

 

INTRODUCTION 

The MCX-610 is a range extender designed to relay digital data 
between wireless devices and a control panel. Repeater links are 
required when the control panel is beyond the range of at least 
some of the devices and is therefore incapable of receiving 
transmissions directly (see Figure 1).  
Devices whose message transmissions need to be repeated by 
the repeater must be enrolled to the repeater and to the control 
panel. 

Features 

  Supports 1way and 2way

 keyfob and detector devices 

 Mains powered 

  36 hours backup battery (rechargeable) 

  Front and back tamper protected 

  Enrolment and test buttons 

  Diagnostic of installation performance 

  Power fail indication (greed LED) 

  Activity (RF) indication (blue LED) 

 

Compatible with PowerMaxExpress PowerMaxComplete 
PowerMaxPro, P and PowerMax1 versions 

 Indoor environment 

Note:

 MCX-610 does not support wireless sirens and repeater 

chains. 

MCX-610

POWERMAX

CONTROL PANEL

Keyfob

Door or window

open/close detector

Motion detector

Two-way

Keyfob

Smoke detector

 

Figure 1

 

-

 Repeater Configuration 

                                                 

 The 

MCT-237 2way keyfob is supported by MCX-610 starting 

from MCT-237 partition version and above.

 

 

2. SPECIFICATIONS 

Frequency Band (MHz):

 

Europe:

 868.95 and 433.92 

USA & canada:

 315 

Antenna: 

Diversity antenna 

Enrolled devices:

 Up to 50 devices may be enrolled to the repeater. 

Communication Protocol: 

PowerCode 

AC Power Supply: 

AC to AC adaptor.  

120 VAC, 60 Hz / 9 VAC, 0.35 A min. (in the U.S.A.)  

230 VAC, 50 Hz / 9 VAC, 0.35 A min. 

For Europe:

 Unit shall be powered by 9VAC only by suitably 

rated (min. 0.35A rated output, 49°C permitted ambient) SELV 
(safety extra low voltage) Limited Power Source (LPS) AC/AC 
transformer. 

Backup Battery: 

4.8-Volt 1300 mAh NiMH rechargeable. 

Caution:

 Risk of explosion if battery is replaced by an incorrect 

type. Dispose of used batteries according to the manufacturer's 

instructions.

 

Current drain at 5.7 VDC:

 90 mA

 

Battery Backup Duration

 (with fully charged 1300 mA/h battery) 

36 hours:  

LED indicator:

 Green LED lights when AC power on. Blue LED 

lights during transmission. 

Supervision:

 A periodic supervision message is transmitted 

automatically once every 15 minutes at 433.92 and 868.95 MHz 
and once every hour at 315 MHz. 

Complies with Standards

Europe CE:

 EN 300220, EN 301489, EN 50130-4, EN 60950 

USA:

 CFR 47 part 15,  

Canada:

 RSS 210

 

Operating Temperature:

 0°C to 49°C (32°F to 120°F).  

Dimensions (H x W x D):

 161x161x50mm (6-7/16 x 6-7/16 x 1-3/4 

in) 

Weight:

 (with battery)

:

 470g (16.5 oz.) 

3. FUNCTION 

3.1 Service Messages 

In addition to repeating messages of enrolled devices, the 
MCX-610 generates the following event codes automatically:  

 Low Battery 

 Tamper 

 Supervision.  

3.2 Indications 

Green LED: 

lights when AC power is available

 

Blue LED:

 lights during transmission 

Reviews: