Visonic MCR-300/UART User Manual Download Page 4

 

Figure 3. Specific Detector ID window 

PowerCode Message Definitions: 

Display 

field

 

Name

 

Definition

 

1

 

Jamming

 

0 = No jamming 
E = European STD jamming level 
U = USA STD jamming level

 

2

 

Quality of RF 
signal

 

POOR / GOOD / STRONG

 

3

 

ID 

 

The detector's ID (6 characters) 

 

4

 

Data 

 

7 6 5 4 3 2 1 0 (see Para.4.3)

 

5

 

Time of event

 

hh:mm:ss (24 h format) 

7.

  The system now begins to monitor the enrolled detectors. The 

window will display the detectors you selected as shown in 
Figure 3. 

Note: The PowerCode Message Definitions table explains how to 
read the data. The Definition of DATA bits in a PowerCode 
Message table explains each bit of the DATA field in a 
PowerCode message. 

8.

  Click X on the top right corner of the window to end the monitoring 

and to close the window. 

9.

  A new window will open; click End Now. 

Definition of DATA bits in a PowerCode Message: 

Bit

 

Name

 

Value

 

Meaning

 

0

 

Tamper

 

1

 

Tamper event

 

1

 

Alarm

 

1

 

Alarm event

 

2

 

Low Battery

 

1

 

Low battery at transmitter

 

 

 

3

 

Working bit

 

0

 

Else

 

1

 

Transmitter has a restore 
capability, e.g. Magnet

 

4

 

Restore

 

0

 

Transmitter with no restore, e.g. 
PIR detector

 

1

 

Supervised transmitter

 

5

 

Supervise

 

0

 

Non-supervised transmitter, e.g. 
Panic button

 

 

 

1

 

Transmitter works in a Spider 
system (Not relevant)

 

6

 

SpiderNet

 

0

 

A regular transmitter, not in a 
Spider system

 

1

 

The transmitter is a Repeater. 
Displays messages received 
from a repeater in the system.

 

7

 

Repeater

 

0

 

Any other transmitter 

 

5.3 CodeSecure - Viewing Specific 

Keyfob IDs 

To view specific keyfob IDs, you need to enroll the required keyfobs 
by filling a simple .txt file to provide details of the keyfob ID. To 
perform this, follow the instructions in section 4.2. 
Figure 4 displays the messages sent by a keyfob, where all four 
keyfob buttons were pressed consecutively. 

 

Figure 4. Specific Keyfob ID window 

The CodeSecure Messages table provides the definition of each field 
in a keyfob message. 

CodeSecure Messages: 

Display 

field

 

Name

 

Definition

 

1

 

Jamming

 

0 = No jamming 
E = European standard jamming 
U = USA jamming

 

2

 

Quality of RF 
signal

 

POOR / GOOD / STRONG

 

3

 

ID 

 

7 character ID, for example, 
015C613

 

3

 

FUNC

 

Button number; the 4 buttons have 
code numbers 0010, 0100, 1000, 
0001

 

4

 

SYNC

 

Transmission serial number

 

6

 

Time of event

 

hh:mm:ss (24 h format) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARRANTY

 

 

Visonic Ltd. and/or its subsidiaries and its affiliates ("the Manufacturer") warrants its 
products hereinafter referred to as "the Product" or "Products" to be in conformance with 
its own plans and specifications and to be free of defects in materials and workmanship 
under normal use and service for a period of twelve months from the date of shipment by 
the Manufacturer.  The Manufacturer's obligations shall be limited within the warranty 
period, at its option, to repair or replace the product or any part thereof. The Manufacturer 
shall not be responsible for dismantling and/or reinstallation charges. To exercise the 
warranty the product must be returned to the Manufacturer freight prepaid and insured. 

This warranty does not apply in the following cases: improper installation, misuse, 
failure to follow installation and operating instructions, alteration, abuse, accident or 
tampering, and repair by anyone other than the Manufacturer. 

This warranty is exclusive and expressly in lieu of all other warranties, obligations or 
liabilities, whether written, oral, express or implied, including any warranty of 
merchantability or fitness for a particular purpose, or otherwise.  In no case shall the 
Manufacturer be liable to anyone for any consequential or incidental damages for breach 
of this warranty or any other warranties whatsoever, as aforesaid. 

This warranty shall not be modified, varied or extended, and the Manufacturer does not 
authorize any person to act on its behalf in the modification, variation or extension of this 
warranty. This warranty shall apply to the Product only.  All products, accessories or 
attachments of others used in conjunction with the Product, including batteries, shall be 
covered solely by their own warranty, if any.  The Manufacturer shall not be liable for any 
damage or loss whatsoever, whether directly, indirectly, incidentally, consequentially or 
otherwise, caused by the malfunction of the Product due to products, accessories, or 
attachments of others, including batteries, used in conjunction with the Products. 

The Manufacturer does not represent that its Product may not be compromised and/or 
circumvented, or that the Product will prevent any death, personal and/or bodily injury 
and/or damage to property resulting from burglary, robbery, fire or otherwise, or that the 
Product will in all cases provide adequate warning or protection. User understands that a 
properly installed and maintained alarm may only reduce the risk of events such as 
burglary, robbery, and fire without warning, but it is not insurance or a guarantee that such 
will not occur or that there will be no death, personal damage and/or damage to property 
as a result. 

The Manufacturer shall have no liability for any death, personal and/or bodily injury 
and/or damage to property or other loss whether direct, indirect, incidental, 
consequential or otherwise, based on a claim that the Product failed to function. 
 
However, if the Manufacturer is held liable, whether directly or indirectly, for any loss or 
damage arising under this limited warranty or otherwise, regardless of cause or origin, the 
Manufacturer's maximum liability shall not in any case exceed the purchase price of the 
Product, which shall be fixed as liquidated damages and not as a penalty, and shall be the 
complete and exclusive remedy against the Manufacturer. 

Warning: The user should follow the installation and operation instructions and among 
other things test the Product and the whole system at least once a week. For various 
reasons, including, but not limited to, changes in environmental conditions, electric or 
electronic disruptions and tampering, the Product may not perform as expected.  The user 
is advised to take all necessary precautions for his/her safety and the protection of his/her 
property. 

6/91 

 

 

W.E.E.E. Product Recycling Declaration

For  information regarding the recycling  of this product  you must contact the  company from which you orignially purchased it. If you are discarding this product and not 
returning it for repair then you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste. 
Directive 2002/96/EC Waste Electrical and Electronic Equipment.

 

 

 

VISONIC LTD. (ISRAEL): 

P.O.B 22020 TEL-AVIV 61220 ISRAEL. PHONE: (972-3) 645-6789, FAX: (972-3) 645-6788 

VISONIC INC. (U.S.A.): 

65 WEST DUDLEY TOWN ROAD, BLOOMFIELD CT 06002-1376. PHONE: (860) 243-0833, (800) 223-0020 FAX: (860) 242-8094 

VISONIC LTD. (UK): 

 

FRASER ROAD, PRIORY BUSINESS PARK, BEDFORD MK44 3WH. PHONE: (0870) 730-0800 FAX: (0870) 730-0801 

INTERNET:  

WWW.VISONIC.COM 

©

VISONIC LTD. 2005      MCR-300/UART         DE3140U (REV. 0,  11/05)

 

 

 

 

 

 

DE3140U 

Summary of Contents for MCR-300/UART

Page 1: ...GH Baud rate 9600 Parity bit None Data bit 8 Stop bit 1 UART interface 2 Integral Antennas diversity reception allowing high performance reception overcoming in band interference Length 80mm Supply Voltage 5 VDC 5 Current Consumption 15 mA 5 VDC 2 MGC Manual Control Gain MGC High 5V Sensitivity attenuation 30dB MGC High impedance Normal Sensitivity Note Do not connect MGC to GND Operating Temperat...

Page 2: ...ssage will be sent again The Receiver Module sends a Supervision message using a Control message every minute Any Data message or Control message successfully sent is also considered a supervision message Timer of supervision at the Receiver Module is cleared after every message that is sent An acknowledge message will be sent by the Control Panel to the Receiver Module after every message sent by...

Page 3: ...n window The open window is a reception of a transmission where the synchronization counter is 1 to 16 higher than the previous counter value received The reception of such a signal will result in an immediate counter update by the control panel program and the appropriate outputs being activated If the transmitter is pressed more than 16 times out of range of the receiver resynchronization needs ...

Page 4: ...nty of merchantability or fitness for a particular purpose or otherwise In no case shall the Manufacturer be liable to anyone for any consequential or incidental damages for breach of this warranty or any other warranties whatsoever as aforesaid This warranty shall not be modified varied or extended and the Manufacturer does not authorize any person to act on its behalf in the modification variati...

Reviews: